N7201A618E00_0309.pdf - 第62页

NPM–W 2 EJM7DE-MB-02 -1T-00 Terma l Regulator 1 Communication Error Terma l Regulator 2 Heater Error Terma l Regulator 1 Heater Error Terma l Regulator 2 Thermocouple Error Terma l Regulator 1 Thermocouple Error Error Me…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
16-Nozzle HeadθPCB
Fuse Disconnection
16-Nozzle HeadθPCB
Temperature Error
16-Nozzle Head θPCB
Voltage Error
16-Nozzle Head Z PCB
Fuse Disconnection
16-Nozzle Head Z PCB
Temperature Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
CPU temperature at the 16-
nozzle mount head Z-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40111
Fuse of the 16-nozzle mount
head Z-axis control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40112
Voltage at the 16-nozzle
mount head θ-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40113
CPU temperature at the 16-
nozzle mount head θ-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40114
Fuse of the 16-nozzle mount
head θ-axis control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40115
2-1-2-36
NPM–W2 EJM7DE-MB-02-1T-00
Termal Regulator1
Communication Error
Termal Regulator2 Heater
Error
Termal Regulator1 Heater
Error
Termal Regulator2
Thermocouple Error
Termal Regulator1
Thermocouple Error
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 19
Error Code
Error Message
Cause Inspection and Solution
Miswiring^ broken wires or
short-circuit of the
thermocouple in the thermal
regulator
(Self-diagnosis error
occurred.)
Contact PFSC.
40116
Miswiring^ broken wires or
short-circuit of the
thermocouple in the thermal
regulator
(Self-diagnosis error
occurred.)
Contact PFSC.
40117
Broken heater cable or
disconnected heater
thermocouple.
(Self-diagnosis error
occurred.)
Contact PFSC.
40118
Broken heater cable or
disconnected heater
thermocouple.
(Self-diagnosis error
occurred.)
Contact PFSC.
40119
Error occurred in
communication between the
head board and the thermal
regulator board.
(Self-diagnosis error
occurred.)
Contact PFSC.
40120
2-1-2-37
NPM–W2 EJM7DE-MB-02-1T-00
3-Nozzle Head PCB
Voltage Error
Nozzle Wiping Station
Setting Error
XY Beam Device Error
Termal Regulator2
Communication Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Error occurred in
communication between the
head board and the thermal
regulator board.
(Self-diagnosis error
occurred.)
Contact PFSC.
40121
Failed to detect the PNP
information of the X/Y axes
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[PnP] and make sure the X/Y axes
are properly detected, and contact
PFSC.
40122
Any of the following causes
is likely:
1) Nozzle wiping station (for
dispense head only) not set
properly.
2) Component ejection box
has been set.
(Self-diagnosis error
occurred.)
Set the nozzle wiping station
properly.
40123
Voltage at the 3-nozzle
mount head control board
has dropped abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40124
2-1-2-38