N7201A618E00_0309.pdf - 第111页
NPM–W 2 EJM7DE-MB-02 -1T-00 No trans syringe PCB Vacuum Error Stop at S-tape sense PCB warp set limit abnormal Can't PCB warp correction PCB warp gradient abnormal Solutions to errors Error Code Error Message Cause …

NPM–W2 EJM7DE-MB-02-1T-00
Nozzle barcode recog
error
Syringe trans empty
Trans auto-supply error
Trans material empty
Height Measurement Error
Error
Message
Troubleshooting
2-1-3
Single stop error 21
Error Code
Error Message
Cause Inspection and Solution
Error occurred during
measurement of height
sensor.
(Single stop error occurred.)
Check the situation of the error
occurred and error message, and
contact PFSC.
40426
Material in the transcript table
is insufficient.
(Single stop error occurred.)
Supply the material to the stamper
table.
40427
Any of the following causes
is likely:
1) Tip of the syringe is
clogged.
2) Transcript material for the
syringe is insufficient.
3) Syringe not installed
properly.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Check the tip of the syringe.
2) Supply transcript material to the
syringe.
3) Make sure the syringe is installed.
40428
Transcript material in the
syringe is insufficient.
(Single stop error occurred.)
Supply transcript material to the
syringe.
40429
Nozzle in the changer to be
used for production does not
agree with the one saved in
the production data.
(Single stop error occurred.)
Check the barcode of the target
nozzle in the changer.
40430
2-1-3-40

NPM–W2 EJM7DE-MB-02-1T-00
No trans syringe
PCB Vacuum Error
Stop at S-tape sense
PCB warp set limit
abnormal
Can't PCB warp correction
PCB warp gradient
abnormal
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
PCB is warped too much.
(Single stop error occurred.)
Check the PCB.
40431
PCB is warped too much.
(Single stop error occurred.)
Check the PCB.
40432
PCB is warped too much.
(Single stop error occurred.)
Check the PCB.
40433
Splicing tape detected.
(Single stop error occurred.)
Check the splicing tape.
40434
Vacuum pressure for
vacuum-holding PCB
dropped. PCB may have not
been set properly.
(Single stop error occurred.)
Check the condition of the PCB.
After checking, set the PCB properly
and resume production.
40435
The syringe is not attached
correctly.
(Single stop error happened.)
Please check attachment of the
syringe.
40436
2-1-3-41

NPM–W2 EJM7DE-MB-02-1T-00
Momentary Power OFF
Air Pressure Error
Tray parts remain load
error
Error
Message
Troubleshooting
2-1-3
Single stop error 22
Error Code
Error Message
Cause Inspection and Solution
Fail to load the parts remain
from tray pallet memory.
(Single stop error occurred.)
1.Please confirm if the tray pallet is
exist in tray pallet arrange and load
position.2.Please confirm if it can
write and load in applicable tray
pallet memory.3.Please contact
PFSC when above1.2confirm result
problem is nothing.
40437
Abnormal air pressure.
(Single stop error occurred.)
Take any of the following measures:
1)Please adjust the regulator when
the supplied air pressure is low.
Please refer to the operating
instruction(Maintenance
articles)about setting pressure.
2)If the air pressure detection
setting(Low limit setting) is too
high, error occurs. Please set the
air pressure detection value to
0.4MPa.
40450
Power supply may have
been stopped momentarily
due to power failure.
(Single stop error occurred.)
Check the voltage of the power
supply in the plant. Turn ON the
power and resume production. If the
error persists, contact PF
40451
2-1-3-42