N7201A618E00_0309.pdf - 第72页
NPM–W 2 EJM7DE-MB-02 -1T-00 Parts Standing Error Parts Re cognition Error Error Message Troubleshooting 2-1-3 Sing le stop er r o r 2 Error Code Error Message Cause Inspection and Solution Any of the following causes is …

NPM–W2 EJM7DE-MB-02-1T-00
Part Pickup Error
Stock Parts Empty
Parts Empty Stop
Parts Empty Occurs
Parts Empty Warning
Error
Message
Solutions to errors
Troubleshooting
2-1-3
Single stop error 1
Error Code
Error Message
Cause Inspection and Solution
Components are running
short.
(Single stop error occurred.)
Supply the components.
40302
Components have run out.
(Single stop error occurred.)
Supply the components.
40303
Components have run out.
(Single stop error occurred.)
Supply the components.
40304
Stocked components have
run out.
(Single stop error occurred.)
Supply the components.
40305
Any of the following causes
is likely:
1) Invalid component data
height.
2) Improper component feed.
3) Incorrect pickup position.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Correct the component data.
2) Replace the tape feeder.
3) Choose [Arrange] - [Parts
prepare] - [Feeder] - [Pickup
position] and perform teaching of
the component pickup position.
40306
2-1-3-1

NPM–W2 EJM7DE-MB-02-1T-00
Parts Standing Error
Parts Recognition Error
Error
Message
Troubleshooting
2-1-3
Single stop error 2
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Improper components are
set.
2) Incorrect component data
(component dimensions^
etc.)
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Set the correct components.
2) Check the component data
(component dimensions, etc.).
40307
Any of the following causes
is likely:
1) Improper components are
set.
2) Incorrect component data
(component dimensions^
etc.)
3) Component picked up
sideways.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Set the correct components.
2) Check the component data
(component dimensions, etc.).
3) Check the pickup condition.
40308
2-1-3-2

NPM–W2 EJM7DE-MB-02-1T-00
Bad Nozzle Detect
Part Mount Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Component was carried
back without mounting it.
2) Nozzle or filter is clogged
with dust or dirt.
3) Sensor may be at fault.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Remove the remaining
components from the nozzles and
restart the machine.
2) Clean the nozzle and filter.
3) Choose [Machine] - [Adjust] -
[Head] - [Vac output check] and if
any problem is found, contact
PFSC.
40309
Pickup or recognition error
occurs frequently at a
specific nozzle.
(Single stop error occurred.)
Choose [Machine] - [Set] - [Head] -
[Bad head] and identify the cause
(pickup error or recognition error).
Then perform appropriate
maintenance.
40310
2-1-3-3