N7201A618E00_0309.pdf - 第252页
NPM–W 2 EJM7DE-MB-02 -1T-00 IspBox MainSys Inspector box initialization error IspBox MainSy s Hard disk capacity no t enough erro r IspBox MainSys Make the LNB work folder error IspBox MainSys Machine command Initializat…

NPM–W2 EJM7DE-MB-02-1T-00
IspBox MainSys LNB
connection error
IspBox MainSys Inspector
head communication error
IspBox MainSys Hardware
abnormal
IspBox MainSys Snsr
calibration Taken picture
save error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Captured image could not be
saved properly.
(Failed to save captured
image.)
Check the network connection. Then,
restart the machine.
1885
Malfunction of hardware was
detected.
(Hardware malfunction
detected.)
Replace the failed component of the
hardware. Contact PFSC.
1886
Command to the camera
failed to be sent properly.
(Failed to set camera gain.)
Restart the machine. If the error
persists, contact PFSC.
1887
Communication with LNB
failed.
(Failed to establish
communication with LNB.)
Check the network connection. Then,
restart the machine.
1888
2-1-4-82

NPM–W2 EJM7DE-MB-02-1T-00
IspBox MainSys Inspector
box initialization error
IspBox MainSys Hard disk
capacity not enough error
IspBox MainSys Make the
LNB work folder error
IspBox MainSys Machine
command Initialization
command error
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
42
Error Code
Error Message
Cause Inspection and Solution
Initial commands were sent
more than once from the
machine.
(Multiple initialization
commands received from
machine.)
Restart the machine.
1889
Work folder for LNB could
not be created.
(Failed to create LNB work
folder.)
Check the network connection. Then,
restart the machine.
1890
Hard disk space is
insufficient.
(Insufficient hard disk space)
Check the available hard disk space.
1891
Invalid head type
(Unsupported head type was
notified.)
After turning OFF the machine
power, check the mounted head. If
the error persists, contact PFSC.
1892
2-1-4-83

NPM–W2 EJM7DE-MB-02-1T-00
IspBox SubSys Camera IF
board error
IspBox SubSys
Communication error
IspBox SubSys
Communication error
IspBox SubSys Abnormal
IspBox MainSys RPC
communication error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(RPC communication failed.)
Restart the machine. If the error
persists, contact PFSC.
1893
Improper procedure was
taken in software processing.
(Error occurred in sub
system.)
Restart the machine. If the error
persists, contact PFSC.
1894
Improper procedure was
taken in software processing.
(Process specified in
communication not found.)
Restart the machine. If the error
persists, contact PFSC.
1895
Improper procedure was
taken in software processing.
(Transmitted parameters not
correct.)
Restart the machine. If the error
persists, contact PFSC.
1896
Improper procedure was
taken in software processing.
(Failed to set configuration
data.)
Restart the machine. If the error
persists, contact PFSC.
1897
2-1-4-84