N7201A618E00_0309.pdf - 第67页

NPM–W 2 EJM7DE-MB-02 -1T-00 LW16-Nozzle Head Z PCB Temper ature Erro r LW16-nozzle head Z PCB Voltage Error Outside input single stop error PCB Vacuum Pump Thermal Error Solutions to errors Error Code Error Message Cause…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Safety Relay Reset is
abnormal.
Opposing Y Axis Posi
Error
(Opposing Supply No
Exist)
Opposing Y Axis Posi
Error
(Opposing Supply Exist)
Ceiling Fan2 Error
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 21
Error Code
Error Message
Cause Inspection and Solution
Ceiling fan stopped.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Check the fan for any
interference with obstacles.
2) Make sure there is no
disconnected wire.
40132
Opposite X/Y axes stopped
within the range of the X/Y
axes.
(Self-diagnosis error
occurred.)
Move the opposite X/Y axes close to
the origin position manually.
40133
Opposite X/Y axes are out of
the turnout position.
(Self-diagnosis error
occurred.)
Move the opposite X/Y axes to the
turnout position manually.White
label is attached on the Y-axis as
the turnout position.Make sure that
the end of the X/Y axis falls within
the white label.
40134
Safety relay reset error
occurred. Since the safety
cover was opened for a
moment^ the safety relay
cannot be reset.
(Self-diagnosis error
occurred.)
Widely open the front or rear safety
cover once and then close it.
40135
2-1-2-41
NPM–W2 EJM7DE-MB-02-1T-00
LW16-Nozzle Head Z PCB
Temperature Error
LW16-nozzle head Z PCB
Voltage Error
Outside input single stop
error
PCB Vacuum Pump
Thermal Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Vacuum pump for
vacuum-holding PCB is at
fault.
2) Improper setting of
overcurrent protection for
the thermal relay
(Self-diagnosis error
occurred.)
Reset the thermal relay and choose
[Machine] - [Adjust] - [All] - [Output
confirm] to check the vacuum pump
for vacuum-holding PCB for proper
operation. If any problem is found,
contact PFSC.
40136
Single stop requested by the
special system developed by
the customer.
(Self-diagnosis error
occurred.)
Reset the request for single stop
from the customer's special system.
Choose [Machine] - [Adjust] - [All] -
[Input confirm] to check the input
status of single stop.
40137
Voltage at the LW16-nozzle
mount head Z-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40138
CPU temperature at the
LW16-nozzle mount head Z-
axis control board has
exceeded the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40139
2-1-2-42
NPM–W2 EJM7DE-MB-02-1T-00
Multi Recog Cam voltage
warning
LW16-Nozzle HeadθPCB
Fuse Disconnection
LW16-Nozzle HeadθPCB
Temperature Error
LW16-Nozzle HeadθPCB
Voltage Error
LW16-Nozzle Head Z PCB
Fuse Disconnection
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 22
Error Code
Error Message
Cause Inspection and Solution
Fuse of the LW16-nozzle
mount head Z-axis control
board has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40140
Voltage at the LW16-nozzle
mount head θ-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40141
CPU temperature at the
LW16-nozzle mount head θ-
axis control board has
exceeded the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40142
Fuse of the LW16-nozzle
mount head θ-axis control
board has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40143
Voltage at the multi recog
camera control board has
dropped abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40144
2-1-2-43