N7201A618E00_0309.pdf - 第285页

NPM–W 2 EJM7DE-MB-02 -1T-00 Servo Switch Off Emergency Stop Switch On Air Pressure Abnormality Solutions to errors Error Code Error Message Cause Inspection and Solution Operation wa s attempted when the supply air press…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Other Error
(Software Monitoring)
Other Error
(Communication)
Other Error
(Software)
Other Error
(Hardware)
Other Error
(Driver)
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
58
Error Code
Error Message
Cause Inspection and Solution
Error with unanalyzable
cause occurred on the driver.
(Other error (driver)
occurred.)
Turn OFF power once and restart
the machine. If the error persists,
contact PFSC.
2204
Error with unanalyzable
cause occurred on the
hardware.
(Other error (hardware)
occurred.)
Turn OFF power once and restart
the machine. If the error persists,
contact PFSC.
2205
Error with unanalyzable
cause occurred on the
software.
(Other error (software)
occurred.)
Turn OFF power once and restart
the machine. If the error persists,
contact PFSC.
2206
Error with unanalyzable
cause occurred in
communication.
(Other error (communication)
occurred.)
Turn OFF power once and restart
the machine. If the error persists,
contact PFSC.
2207
Error with unanalyzable
cause occurred in software
monitoring.
(Other error (software
monitoring) occurred.)
Turn OFF power once and restart
the machine. If the error persists,
contact PFSC.
2208
2-1-4-115
NPM–W2 EJM7DE-MB-02-1T-00
Servo Switch Off
Emergency Stop Switch
On
Air Pressure Abnormality
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Operation was attempted
when the supply air pressure
was abnormal.
(Abnormal air pressure
occurred.)
Take any of the following measures:
1)Please adjust the regulator when
the supplied air pressure is low.
Please refer to the operating
instruction(Maintenance
articles)about setting pressure.
2)If the air pressure detection
setting(Low limit setting) is too
high, error occurs. Please set the
air pressure detection value to
0.4MPa.
2209
Emergency stop switch has
been pressed.
(Emergency stop switch ON
error detected.)
Turn the emergency stop switch
clockwise to reset.(One position
each at front and rear)If the error
persists, the switch may be
broken.Contact PFSC.
2210
Operation was attempted
when the servo switch was
OFF.
(Servo switch turned OFF.)
Turn ON the servo switch (One
position each at front and rear).If the
error persists, the switch may be
broken. Choose [Machine] - [Adjust]
- [All] - [Input confirm] and make
sure the servo switch ON is
displayed when the servo switch is
ON and the Servo Off is shown
when the servo switch is OFF.
2211
2-1-4-116
NPM–W2 EJM7DE-MB-02-1T-00
LNB barcode analysis
time out
LNB barcode analysis
error
LNB process error
Other Error
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
59
Error Code
Error Message
Cause Inspection and Solution
Error with unanalyzable
cause occurred.
(Other error occurred.)
Turn OFF power once and restart
the machine. If the error persists,
contact PFSC.
2212
Error detected from LNB.
(LNB processing error
occurred.)
Check the situation of the error
occurred and error message, and
contact PFSC.
2220
LNB failed to analyze the
PCB barcode.
(LNB barcode analysis error
occurred.)
Take any of the following measures:
1) Check the PCB ID setting of LNB.
2) Check the PCB code setting of
DGS.
2221
Failed to obtain the result of
PCB barcode analysis from
LNB and timeout occurred.
(LNB barcode analysis
timeout error occurred.)
Take any of the following measures:
1) Check the PCB ID setting of LNB.
2) Check the PCB code setting of
DGS.
2222