N7201A618E00_0309.pdf - 第231页
NPM–W 2 EJM7DE-MB-02 -1T-00 Communication : Received Data Size Error Communication : Argument Pointe r NULL Error Communication : Complete Interrupt Timeout Communication : Command Enabling Timeout Communication : Check …

NPM–W2 EJM7DE-MB-02-1T-00
Communication:
Data Length Error
Communication:
Hand Shake Error
Communication:
Communication Default
Unconnected Error
Communication:
Head Communication
Error
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
31
Error Code
Error Message
Cause Inspection and Solution
Error occurred in
communication with the head
or feeder cart.
(Communication error
occurred.)
Clean the drawer connectors for
connecting head and feeder cart,
and check the wiring to be
connected to them. If the error
persists, contact PFSC.
1740
Connection module
connected to the machine
failed to be detected.
(Communication error
occurred.)
Check the connection of the feeder
cart.
1741
Error occurred in
communication with the head
or feeder cart.
(Communication error
occurred.)
Clean the drawer connectors for
connecting head and feeder cart,
and check the wiring to be
connected to them. If the error
persists, contact PFSC.
1742
Improper procedure was
taken in software processing.
(Invalid data length found in
communication.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1743
2-1-4-61

NPM–W2 EJM7DE-MB-02-1T-00
Communication:
Received Data Size Error
Communication:
Argument Pointer NULL
Error
Communication:
Complete Interrupt
Timeout
Communication:
Command Enabling
Timeout
Communication:
Check Sum Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Check sum error occurred in
the communication data from
the head or feeder cart to the
host.
(Communication error
occurred.)
Clean the drawer connectors for
connecting head and feeder cart,
and check the wiring to be
connected to them. If the error
persists, contact PFSC.
1744
Improper procedure was
taken in software processing.
(Improper procedure was
found in synchronization
process during head
communication.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1745
Improper procedure was
taken in software processing.
(Timeout error occurred in
completion interrupt.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1746
Improper procedure was
taken in software processing.
(Argument pointer is null.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1747
Improper procedure was
taken in software processing.
(Improper received data
size.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1748
2-1-4-62

NPM–W2 EJM7DE-MB-02-1T-00
Communication:
Specified File Size Acquire
Error
Communication:
Specified File Open Error
Communication:
Status Communication
Error
Communication:
Status Communication
Stopping Error
Communication:
Completion Error
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
32
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Transmission command not
executed properly.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1749
Improper procedure was
taken in software processing.
(Function to obtain status
was called while status
communication was
stopped.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1750
Improper procedure was
taken in software processing.
(Error occurred in status
communication.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1751
Improper procedure was
taken in software processing.
(Cannot open ROMless file.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1752
Improper procedure was
taken in software processing.
(Improper ROMless file size.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1755
2-1-4-63