N7201A618E00_0309.pdf - 第83页

NPM–W 2 EJM7DE-MB-02 -1T-00 Main Body Cooling Fan Alarm Vacuum pump over heat Tray Position Recog Error Serial Ca lib Value Range Over Solutions to errors Error Code Error Message Cause Inspection and Solution Mark recog…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Serial Calib Recog Error
Mount Pos Recog Error
Error
Message
Troubleshooting
2-1-3
Single stop error 7
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1)Recognition mark is out of
camera's view.
2)Recognition error occurred
due to dirt on PCB.
3) Mounting point recognition
coordinates are incorrect.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Move the camera to the
recognition mark position using the
inching function and press the [Re-
recognize] button.
2) After cleaning the recognition
camera and PCB, press the [Re-
recognize] button. If the
recognition error occurs again,
press the [No Recognition] or
[Pass] button.[No Recognition]:
Proceeds to the next process
without performing
recognition[Pass]: Pass the PCB.
3) Choose [Production data] -
[Correct] - [Mount] and enter the
mounting point recognition
coordinates correctly.
40333
Mark recognition error
occurred in time-lapse
change calibration.
(Single stop error occurred.)
Take any of the following measures:
1) Make sure the mark surface at
calibration cylinder is not dirty.
Perform cleaning if found dirty
2) Make sure the head camera light
is lit properly. If not lit, contact
PFSC.
40334
2-1-3-12
NPM–W2 EJM7DE-MB-02-1T-00
Main Body Cooling Fan
Alarm
Vacuum pump over heat
Tray Position Recog Error
Serial Calib Value Range
Over
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Mark recognition result for
time-lapse change calibration
has exceeded the setting
value.
(Single stop error occurred.)
Make sure the mark surface at
calibration cylinder is not dirty.
Perform cleaning if found dirty.
40335
Recognition mark is out of
camera's view.
(Single stop error occurred.)
Take measures in the following
order.
1) Move the camera to the
recognition mark position using the
inching function and press the [Re-
recognize] button.
2) If the recognition error occurs
again, move the camera to the
recognition mark position using the
inching function and press the
[Manual set] button.[Manual set]:
Save the inching amount as the
offset.
40336
1) Vacuum pump is at fault.
2) Overcurrent setting for
thermal relay protection has
not been set properly.
(Single stop error occurred.)
Reset the thermal relay. Choose
[Machine] - [Adjust] - [All] - [Output
confirm] and check the vacuum
pump for proper movement. If any
problem is found, contact PFSC.
40337
Cooling fan for the machine
may be at fault or cable may
be broken.
(Single stop error occurred.)
Make sure the cooling fan for the
machine is turning.
40338
2-1-3-13
NPM–W2 EJM7DE-MB-02-1T-00
item name unmatched
LNB Comm. Abnormality
All Block NG Judgement
Motor Cooling Fan Alarm
Error
Message
Troubleshooting
2-1-3
Single stop error 8
Error Code
Error Message
Cause Inspection and Solution
Cooling fan for the Y-axis
motor may be at fault or
cable may be broken.
(Single stop error occurred.)
Make sure the cooling fan for the Y-
axis motor is turning.
40339
All patterns on the PCB were
detected as bad patterns at
bad mark judgement.
(Single stop error occurred.)
Take any of the following measures:
1) Remove the applicable PCB from
the machine and restart production.
2) To pass the PCBs with all bad
patterns, enable the [All pattern
bad board pass].
40340
Communication failed due to
broken cable in the
communication system or
trouble such as power OFF
of the hub.
(Single stop error occurred.)
Check the communication system
and make sure the power to the hub
is turned ON.When simplified LNB
is used, make sure the power to the
PC is turned ON. To restart the LNB
conveyor or simplified LNB PC
during production, set all the
machines on the line to the cycle
stop mode or return to the main
menu to restart production.
40341
Mismatch occurred in the
product name.
(Single stop error occurred.)
Make sure the product name agrees
with that of the previous process.
40342
2-1-3-14