NPM–W 2 EJM7DE-MB-02 -1T-00 Chip Eject Error Part Drop Solutions to errors Error Code Error Message Cause Inspection and Solution Any of the following causes is likely: 1) Comp onent dropped during after recognition befo…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
PCB Warp Range Over
PCB Warp Measurement
Error
Part Thickness Measure
Error
Nozzle Height Measure
Error
PCB Thickness Measure
Error
Error
Message
Troubleshooting
2-1-3
Single stop error 5
Error Code
Error Message
Cause Inspection and Solution
Feeder or tray not set from
which the component is
picked up.
(Single stop error occurred.)
Make sure that the feeder or pallet is
properly set and the nozzle is
properly set on the head.
40322
Nozzle may be wrong.
(Single stop error occurred.)
Check the nozzle.
40323
Component height data may
be incorrect.
(Single stop error occurred.)
Check the component.
40324
PCB is warped too much.
(Single stop error occurred.)
Check the PCB.
40325
PCB is warped too much.
(Single stop error occurred.)
Check the PCB.
40326
2-1-3-8
NPM–W2 EJM7DE-MB-02-1T-00
Chip Eject Error
Part Drop
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Component dropped
during after recognition
before it was mounted.
2) Nozzle or filter clogged.
3) Component is not
securely picked up by the
nozzle.
4) Sensor may be at fault.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Remove dropped component and
restart the machine.
2) Clean the nozzle and filter.
3) Remove the component and
restart production.
4) Choose [Machine] - [Adjust] -
[Head] - [Vac output check] and if
any problem is found, contact
PFSC.
40327
Any of the following causes
is likely:
1) Recognition error
component failed to be
ejected to the eject box.
2) Nozzle or filter clogged.
3) Sensor may be at fault.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Remove the remaining
components from the nozzles and
restart the machine.
2) Clean the nozzle and filter.
3) Choose [Machine] - [Adjust] -
[Head] - [Vac output check] and if
any problem is found, contact
PFSC.
40328
2-1-3-9
NPM–W2 EJM7DE-MB-02-1T-00
Nozzle Recognition Error
Nozzle Fall
Error
Message
Troubleshooting
2-1-3
Single stop error 6
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Nozzle came off during
pickup or mounting.
2) Filter is clogged.
3) Sensor may be at fault.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Check the nozzle and attach it if it
came off.
2) Clean the filter.
3) Choose [Machine] - [Adjust] -
[Head] - [Vac output check] and if
any problem is found, contact
PFSC.
40329
Recognition error occurred
due to dirty mark^ etc.
(Single stop error occurred.)
Check if the time-lapse change
calibration mark is not dirty. Clean
the mark if dirty.
40330
2-1-3-10