N7201A618E00_0309.pdf - 第260页
NPM–W 2 EJM7DE-MB-02 -1T-00 Communication error System state error Command error IspBox SubSys Sample image save error IspBox take image start timeout Error Message Troubleshooting 2-1-4 Emer genc y stop er r or s 46 Err…

NPM–W2 EJM7DE-MB-02-1T-00
IspBox MainSys PCB skip
notification command
error
Camera IF board DMA
transfer error
Camera IF board
Exposure finish
information deal error
Camera IF board
Exposure finish
information start error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Failed to set the exposure
completion notice of the
camera IF board.)
Restart the machine. If the error
persists, contact PFSC.
1961
Exposure finish information
could not be received.
(Failed to receive the
exposure completion notice
of the camera IF board.)
Check the connection of the camera
link cable.
1962
Image transfer from the
camera IF board to the
inspection box PC failed.
(Failed in DMA transfer of
image from the camera IF
board.)
Check the connection of the camera
link cable.
2001
Improper procedure was
taken in software processing.
(PCB skip information
command notified
incorrectly.)
Restart the machine. If the error
persists, contact PFSC.
2002
2-1-4-90

NPM–W2 EJM7DE-MB-02-1T-00
Communication error
System state error
Command error
IspBox SubSys Sample
image save error
IspBox take image start
timeout
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
46
Error Code
Error Message
Cause Inspection and Solution
Because the IspBOX
process is delayed^ it has
been over the specified time
at the start of taking image.
(Image is taken in inspect
head after the light is off.)
Please restart the auto running. If
the error persists, contact PFSC.
2050
Needful image data lost in
saving sample image.
(Failed to save the sample
image.)
It is possible that the recognition is
wrong in the mark recognition
process.Please confirm the mark
recognition process.
2051
VLC system may be at fault.
(Command error detected by
VLC.)
Contact PFSC.
2053
VLC system may be at fault.
(System error detected by
VLC.)
Contact PFSC.
2054
Connector may be
disconnected.
(Communication error
detected by VLC.)
Check the connection connector.
2055
2-1-4-91

NPM–W2 EJM7DE-MB-02-1T-00
Optical path deviated
Low light intensity
Effective Section overflow
Line number overflow
Sensor Blocked
completely
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
1) Sensor is blocked
completely by some
obstacles.
2) Connector may be
disconnected.
(VLC sensor blocked
completely.)
1) Remove any obstacles. Wipe
away any dirt from the lens if it is
dirty.
2) Check the connector.
2056
VLC system may be at fault.
(Line overflow detected by
VLC.)
Contact PFSC.
2057
VLC system may be at fault.
(Overflow from effective zone
detected by VLC.)
Contact PFSC.
2100
Lens may be dirty.
(Drop in intensity detected by
VLC.)
Clean the lens if dirt is found.
2101
Optical axis is displaced.
(Displacement of the optical
axis detected.)
Check the installation condition of
the VLC sensor.
2103