N7201A618E00_0309.pdf - 第147页
NPM–W 2 EJM7DE-MB-02 -1T-00 Parts Re cognition Error Solutions to errors Error Code Error Message Cause Inspection and Solution The degree of perpendicularity of th e component outer edge (molding) or lead array is incor…

NPM–W2 EJM7DE-MB-02-1T-00
Parts Recognition Error
Parts Recognition Error
Error
Message
Troubleshooting
2-1-3
Single stop error 39
Error Code
Error Message
Cause Inspection and Solution
Angle of parallelism for
component outer shape side
(mold) or electrode
arrangement is improper.
- Opposite side of square
chip component or difference
in angle of opposite side of
lead array components is not
in parallel.
- Lead lengths of mini Tr
component^ etc.^ are not
aligned^ disabling
parallelism in lead
arrangement.
(Recognition error -
Component outer shape
angle (parallelism))
Take any of the following measures:
1) Check the condition of the
electrodes.If the lead length of the
lead array components differs
partly, register the lead length
correctly.
2) Check the component pickup
position and pickup
condition.Make sure the
component pickup position is not
placed at the center and the
component is not likely to be in the
slanted pickup posture.
43041
The degree of
perpendicularity of the
component outer edge
(molding) or lead array is
incorrect.The straight sides
of a square chip or the angle
between adjacent sides of a
lead array component are
not near to 90 degrees.The
lead array of a miniature
transistor or other
component is not
perpendicular because the
leads are not aligned in the
length direction.
(Recognition error -
Component outer edge angle
(perpendicularity))
Take any of the following measures:
1) Check the condition of the
electrodes.If the lead length of the
lead array components differs
partly, register the lead length
correctly.
2) Check the component pickup
position and pickup
condition.Make sure the
component pickup position is not
placed at the center and the
component is not likely to be in the
slanted pickup posture.
43042
2-1-3-76

NPM–W2 EJM7DE-MB-02-1T-00
Parts Recognition Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
The degree of
perpendicularity of the
component outer edge
(molding) or lead array is
incorrect.Opposite sides of a
square chip are not parallel
or the side angles of a lead
array component are not
perpendicular.The lead array
of a miniature transistor or
other component is not
straight or parallel because
the leads are not aligned in
the length direction.
(Recognition error -
Component outer edge angle
(parallelism or
perpendicularity)
Take any of the following measures:
1) Check the condition of the
electrodes.If the lead length of the
lead array components differs
partly, register the lead length
correctly.
2) Check the component pickup
position and pickup
condition.Make sure the
component pickup position is not
placed at the center and the
component is not likely to be in the
slanted pickup posture.
43043
2-1-3-77

NPM–W2 EJM7DE-MB-02-1T-00
Parts Recognition Error
Error
Message
Troubleshooting
2-1-3
Single stop error 40
Error Code
Error Message
Cause Inspection and Solution
The contrast (difference in
brightness) between the
component and background
is not good.Brightness of the
component and the
background of the detection
area are not different enough
to distinguish the
two.Nothing suggestive of a
component was found in the
detection area.
(Recognition error - Image
contrast status)
Take any of the following measures:
1) Check the image status of the
component.If the color level of the
image is not separated on the
image as follows, check the setting
of lamp value or component size
data (outer shape size).<In
component recognition>Shadow
light: Component background in
white/Components in
blackReflective light: Component
background in black/Component
electrode in white
2) Check that the target component
appears in the window.If the target
component does not appear in the
window, check the pickup position
and the component size data
(external size).
43045