NPM–W 2 EJM7DE-MB-02 -1T-00 Parts Re cognition Error Solutions to errors Error Code Error Message Cause Inspection and Solution Electrode wi dth was judged to be invalid.Invalid lead width size of lead component.Invalid …

NPM–W2 EJM7DE-MB-02-1T-00
Parts Recognition Error
Error
Message
Troubleshooting
2-1-3
Single stop error 35
Error Code
Error Message
Cause Inspection and Solution
Electrode shape of detected
recognition target is
invalid.Electrode shape of
ball component is out of
shape.Electrode's end of
lead component is not
rectangular.
(Recognition error -
Electrode shape)
Take any of the following measures:
1) Check the condition of the
component's electrodes.If the end
of the lead components is not
rectangular, set to the shape
closer to the actual shape through
Recognition option: Lead end
shape.Delete the unstable part in
shape from the registered shape
data.
2) Check the image status of the
electrode at the ends.If the shape
of the ends like J-lead component
or curved component is unclear on
the image, adjust the lamp value
and correct the image status.(At
this time, the side lighting is
effective.)For ball array
components, adjust the lamp value
so that the image status of the ball
will be circular.
43031
2-1-3-68

NPM–W2 EJM7DE-MB-02-1T-00
Parts Recognition Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Electrode width was judged
to be invalid.Invalid lead
width size of lead
component.Invalid ball
diameter of ball array
component.
(Recognition error -
Electrode width size)
Take any of the following measures:
1) Check the condition of the
component's electrodes.For lead
components, make sure there is
no variation in lead width.If the
lead width differs partly, register
the width of the component
concerned correctly.
2) Check the image status of the
electrodes.For ball components,
the ball may look smaller than the
actual ball size depending on the
status of the ball shape.In such a
case, adjust the lamp value so that
the image of the ball may be equal
to the entered size.Or correct the
entered value of the back diameter
according to the image status.
3) Check the allowable value for
recognition.If the electrode width
sizes of actual components differ
widely, specify Recognition option:
Lead width/ball diameter limit.
43032
2-1-3-69

NPM–W2 EJM7DE-MB-02-1T-00
Parts Recognition Error
Error
Message
Troubleshooting
2-1-3
Single stop error 36
Error Code
Error Message
Cause Inspection and Solution
Electrode arrangement for
lead or ball array
components is
improper.Electrode column
arranged in linear on data is
not aligned.
(Recognition error -
Electrode arrangement)
Take any of the following measures:
1) Check the condition of the
component's electrodes.For lead
components, make sure there is
no variation in lead length.If the
lead length differs partly, register
the lead length of the component
concerned correctly.
2) Check the image status of the
electrode at the endsIf the shape
of the ends like J-lead component
or curved component is unclear on
the image, adjust the lamp value
and correct the image status.(At
this time, the side lighting is
effective.)
3) If the arrangement of ball array
components is not in lattice-
shaped, specify Shape property:
Irregular array ball.(At this time,
the ball data needs to be taught by
the machine.)
43033
2-1-3-70