N7201A618E00_0309.pdf - 第115页

NPM–W 2 EJM7DE-MB-02 -1T-00 No rec ognition nozzle error Tape ch ange action incomplete Pattern data error Part Recog Err (check drop) Solutions to errors Error Code Error Message Cause Inspection and Solution Error happ…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Nzl Point Abnormal Error
Nzl Height Range Ov
(Recog.)
Nzl Height Det Err
(Recog.)
Tape unset error
Tape off detect error
Error
Message
Troubleshooting
2-1-3
Single stop error 23
Error Code
Error Message
Cause Inspection and Solution
The tape may be dropped out.
(Single stop error occurred.)
Check if the tape is inserted
correctly.
40456
The tape is not set.
(Single stop error occurred.)
Check if the tape is inserted
correctly.
40457
Measurement result is out of
output value.
(Single stop error occurred.)
Check the mounting status of the
nozzle.Make sure that there is no
foreign body on the lens of the parts
recognition camera.Calibrate origin
offset Z-axis and multi recognition
camera offset.
40458
Difference between nozzle
detection result and nozzle
length exceeded the range of
-0.3mm~0.4mm.
(Single stop error occurred.)
Check the nozzle length.Calibrate
origin offset Z-axis and multi
recognition camera offset.
40459
Tip of the nozzle is not planar.
(Single stop error occurred.)
Check the tip of the nozzle and
clean it. Replace the faulty nozzle.
40460
2-1-3-44
NPM–W2 EJM7DE-MB-02-1T-00
No recognition nozzle
error
Tape change action
incomplete
Pattern data error
Part Recog Err
(check drop)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Error happened at the drop
detect before ejecting of the
parts recognition error or
pickup error.
(Recognition error Drop
detect before ejecting)
Please confirm that if there are parts
dropped on the PCB after finishing
the auto running and remove the
PCB.
40463
It is not possible to read the
recognition pattern data of
block match teach or
asymmetric array BGA
teach.Any of the following
causes is likely.
1) Device is not connected.
2) Recognition pattern data
is inexistent.
(Single stop error occurred.)
1) Please confirm the connect state
of LNB or SD card.
2) Please execute block match
teach or asymmetric array BGA
teach.
40464
Failed in tape change action.
(Single stop error occurred.)
Please set the new tape again from
the beginning.
40465
In nozzle confirm
processing^ it is detected
that the necessary nozzle for
recognition isn't arranged in
stocker.
(Single stop error occurred.)
Please set the nozzle to applicable
stocker.
40466
2-1-3-45
NPM–W2 EJM7DE-MB-02-1T-00
PrePickup Insp comm err
(ISS)
PrePickup Insp comm err
(LNB)
PrePickup Insp Error
Error
Message
Troubleshooting
2-1-3
Single stop error 24
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1)Parts direction is wrong.
2)Different parts is set.
3)The recognition data of
pre-pickup inspection is
wrong.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1)Please set correct direction.
2)Please set correct parts.
3)Please modify recognition data of
pre-pickup inspection
40467
The communication state is
abnormal between MC and
LNB.
(Single stop error occurred.)
Take any of the following measures:
1)Please confirm the
communication state between MC
and LNB.
2)Please confirm state or setting of
LNB.
40468
The communication state is
abnormal between LNB and
ISS(Inspection Server
Software).
(Single stop error occurred.)
Take any of the following measures:
1)Please confirm the
communication state between LNB
and ISS.
2)Please confirm state or setting of
ISS.
40469
2-1-3-46