N7201A618E00_0309.pdf - 第249页
NPM–W 2 EJM7DE-MB-02 -1T-00 IspBox MainSys Machine communication error IspBox MainSys Machine communication error IspBox MainSys Production dat a Read error IspBox MainSys Machine command Command abnormal timing error So…

NPM–W2 EJM7DE-MB-02-1T-00
IspBox MainSys
Production data Lot
information error
IspBox MainSys
Production data Parts
information error
IspBox MainSys Mark
correction Information
register error
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
40
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Failed to save mark result
information.)
Restart the machine. If the error
persists, contact PFSC.
1874
Check result data of the
component specified by the
machine does not exist.
(Production data (inspection
data) unmatched between
the machine and the
inspection box.)
Download the production data again.
1875
Lot data specified by the
machine does not exist.
(Lot data unmatched
between the machine and
the inspection box.)
Download the production data again.
1876
2-1-4-79

NPM–W2 EJM7DE-MB-02-1T-00
IspBox MainSys Machine
communication error
IspBox MainSys Machine
communication error
IspBox MainSys
Production data Read
error
IspBox MainSys Machine
command Command
abnormal timing error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Improper procedure was
taken in software
processing.
2) Mismatch of the software
version between the
machine and the inspection
box.
(Production-related
command was notified from
the machine when
production was not
ongoing.)
Take measures shown with the
same number as that of the cause.
1) Restart the machine. If the error
persists, contact PFSC.
2) If the error persists even after the
upgrade, check the situation of the
error occurred and error message,
and contact PFSC.
1877
Production data cannot be
loaded.
(Failed to read production
data.)
Check the production data.
1878
Improper procedure was
taken in software processing.
(Failed to transmit command
to machine.)
Restart the machine. If the error
persists, contact PFSC.
1879
Improper procedure was
taken in software processing.
(Failed to receive command
from machine.)
Restart the machine. If the error
persists, contact PFSC.
1880
2-1-4-80

NPM–W2 EJM7DE-MB-02-1T-00
IspBox MainSys Snsr
calibration Distortion
correction error
IspBox MainSys Snsr
calibration Light measure
error
IspBox MainSys Snsr
calibration Correction post
recog error
IspBox MainSys Whole
board image save error
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
41
Error Code
Error Message
Cause Inspection and Solution
Image could not be saved
properly.
(Failed to save the image.)
Check the available hard disk space.
1881
Calibration post could not be
recognized properly.
(Failed to recognize
calibration post.)
Clean the calibration post.
1882
Brightness of the jig could
not be measured properly.
(Failed to measure the
brightness of jig.)
Clean the jig.
1883
Distortion could not be
corrected properly.
(Failed to correct distortion.)
Clean the jig.
1884
2-1-4-81