NPM–W 2 EJM7DE-MB-02 -1T-00 No Ch anger uni t No Eject BOX Error Message Troubleshooting 2-1-2 Self-dia gnosis er r or s 16 Error Code Error Message Cause Inspection and Solution Any of the following causes is likely: 1)…

NPM–W2 EJM7DE-MB-02-1T-00
Operation Switch Board
Temperature Error
Fan Error Under Base
Ceiling Fan Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Ceiling fan stopped.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1)Check the fan for any interference
with wiring, etc.
2) Make sure there is no
disconnected wire.
40095
Fan under the base stopped.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1)Check the fan for any interference
with wiring, etc.
2) Make sure there is no
disconnected wire.
40096
CPU temperature at the
operation switch board has
exceeded the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40097
2-1-2-30

NPM–W2 EJM7DE-MB-02-1T-00
No Changer unit
No Eject BOX
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 16
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Component ejection box
not set in position.
2) Nozzle wiping station
(only for dispense head)
has been set.
(Self-diagnosis error
occurred.)
Reset the component ejection box
properly.
40098
Nozzle changer not installed.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Install the changer corresponding
to the head.
2) If the error persists even after the
changer is installed, the
connection with the changer may
not be detected.Choose [Machine]
- [Adjust] - [All] - [Input confirm]
and check the connection of
changer.
40099
2-1-2-31

NPM–W2 EJM7DE-MB-02-1T-00
Pre Proc Adjacent Safety
Device Error
There is no feeder cover
or tray feeder
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
No feeder cover. Or tray
feeder not installed.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Attach the feeder cover when the
feeder cart is used.
2) When the tray feeder is used,
install the tray feeder and then
insert the key in the tray feeder
detection switch.
3) If the error persists, choose
[Machine] - [Adjust] - [All] - [Input
confirm] and check that the feeder
cover is attached and the tray
detection switch is connected.
40100
Any of the following causes
is likely:
1) Foreign body found at the
transfer opening.
2) Feeder cover not attached.
3) Emergency stop switch of
the adjoining machine has
been pressed.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Remove any foreign body from
the transfer opening.
2) Attach the feeder cover.
3) Reset the emergency stop status
of the adjoining machine.
40101
2-1-2-32