NPM–W2 EJM7DE-MB-02-1T-00
Feeder Mainte Cnt Over
PCB Bar Code Recog Err
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Recognition mark is out of
camera's view.
2) Recognition error
occurred due to dirt on PCB.
3) Incorrect PCB barcode
recognition coordinates
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Using the inching function, move
the camera to the recognition mark
position and press the [Re-
recognize] button.
2) After cleaning the recognition
camera and PCB, press the [Re-
recognize] button. If the
recognition error occurs again,
move the camera to the
recognition mark position with the
[Pass] button or inching function
and press the [Manual set] button.
[Pass]: Pass the PCB.[Manual
set]: Save the inching amount as
the offset.
3) Choose [Production data] -
[Correct] - [PCB] - [PCB recog.]
and enter the correct PCB
recognition coordinates.
40388
Machine stopped because
the pickup count of the
feeder is beyond the
maintenance count.
(Single stop error occurred.)
Choose [Maintenance] - [Regular
inspection] (feeder maintenance) to
confirm the feeders concerned and
perform maintenance for them.
40389
2-1-3-27
NPM–W2 EJM7DE-MB-02-1T-00
Pst Prc Adjcnt Safe Unit
Err
Pre Prc Adjcnt Safe Unit
Err
Regular Check Error
Error
Message
Troubleshooting
2-1-3
Single stop error 15
Error Code
Error Message
Cause Inspection and Solution
Component information
written into feeder memory
for regular check and
scanned reel barcode
information not matched.
(Single stop error occurred.)
Read the correct reel barcode.
40390
1) Foreign body found at the
transfer opening.
2) Feeder cover not attached.
3) Emergency stop switch of
the adjoining machine has
been pressed.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Remove any foreign body from
the transfer opening.
2) Attach the feeder cover.
3) Release the emergency stop
status of the adjoining machine.
40391
1) Foreign body found at the
transfer opening.
2)Feeder cover not attached.
3) Emergency stop switch of
the adjoining machine has
been pressed.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Remove any foreign body from
the transfer opening.
2) Attach the feeder cover.
3)Release the emergency stop
status of the adjoining machine.
40392
2-1-3-28
NPM–W2 EJM7DE-MB-02-1T-00
Head Error Rate Stop
Feeder Error Rate Stop
No Feeder Cover
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Operation was attempted
without attaching the feeder
cover.
(Single stop error occurred.)
Take any of the following measures:
1) Attach the feeder cover.
2) If the error persists even after the
feeder cover is attached, the
connection with the connector of
the feeder cover may not be
detected. Choose [Machine] -
[Adjust] - [All] - [Input confirm] and
check the connection of the feeder
cover.
40393
Pickup errors and/or
recognition errors have
occurred beyond the bad
feeder error rate set in action
parameters.
(Single stop error occurred.)
Check the condition of the feeder
and clean it if necessary.
40394
Pickup errors and/or
recognition errors have
occurred beyond the bad
head error rate set in action
parameters.
(Single stop error occurred.)
Check the condition of the head and
clean it if necessary.
40395