N7201A618E00_0309.pdf - 第256页

NPM–W 2 EJM7DE-MB-02 -1T-00 IspBox SubSys Pr oduction data not evolved error IspBox SubSys Pr oduction data evolution error IspBox SubSys Mark correction error IspBox SubSys Ins pection template data make error IspBox Su…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
IspBox SubSys Sample
inspection error
IspBox SubSys Inspection
result data Memory
abnormal
IspBox SubSys Inspection
process interrupt
IspBox SubSys Image
data Unmatched error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Necessary image to be
loaded not found in the
view.)
Load the entire PCB image again.
1902
Inspection process was
stopped.
(Inspection process was
interrupted.)
Cancel stopping and resume the
process.
1903
Improper procedure was
taken in software processing.
(Insufficient memory space
of result data.)
Restart the machine. If the error
persists, contact PFSC.
1904
Improper procedure was
taken in software processing.
(Failed to inspect the sample
image.)
Restart the machine. If the error
persists, contact PFSC.
1905
2-1-4-86
NPM–W2 EJM7DE-MB-02-1T-00
IspBox SubSys Production
data not evolved error
IspBox SubSys Production
data evolution error
IspBox SubSys Mark
correction error
IspBox SubSys Inspection
template data make error
IspBox SubSys State
abnormal
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
44
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Application condition is
abnormal.)
Restart the machine. If the error
persists, contact PFSC.
1906
Improper procedure was
taken in software processing.
(Failed to create inspection
template data.)
Restart the machine. If the error
persists, contact PFSC.
1907
Improper procedure was
taken in software processing.
(Failed to register mark result
information.)
Restart the machine. If the error
persists, contact PFSC.
1908
Improper procedure was
taken in software processing.
(Inspection box system error
occurred.)
Restart the machine. If the error
persists, contact PFSC.
1909
Improper procedure was
taken in software processing.
(Inspection box system error
occurred.)
Restart the machine. If the error
persists, contact PFSC.
1950
2-1-4-87
NPM–W2 EJM7DE-MB-02-1T-00
Camera IF board Device
driver error
IspBox SubSys Time out
error
IspBox SubSys Error
IspBox SubSys Production
data error
IspBox SubSys Production
data error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Invalid content was found in
the production data.
(Invalid production data.)
Create the production data again.
Then, download the production data
again.
1951
Failed to get the view data.
(Failed to get the view data.)
Check the applicable components
for inspection in the production data
and download the data again.
1952
Improper procedure was
taken in software processing.
(Inspection box system error
occurred.)
Restart the machine. If the error
persists, contact PFSC.
1953
Improper procedure was
taken in software processing.
(Timeout occurred in
software processing.)
Restart the machine. If the error
persists, contact PFSC.
1954
Improper procedure was
taken in software processing.
(Camera IF board driver
aborted.)
Restart the machine. If the error
persists, contact PFSC.
1955
2-1-4-88