NPM–W 2 EJM7DE-MB-02 -1T-00 Data Set Command Not Issued Error Write EEPROM Error Servo Ready Off Completion Error Interrupt Solutions to errors Error Code Error Message Cause Inspection and Solution Unwanted in terrupt o…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Position Error Interrupt
Exclusive Process Error
Return To Origin Process
Error
Motion Process Error
Motion Preparation Error
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
14
Error Code
Error Message
Cause Inspection and Solution
Servo driver of the target axis
is at fault.
(Operation preparation error
occurred.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1528
Servo driver of the target axis
is at fault.
(Operation process error
occurred.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1529
Servo driver^ motor or origin
sensor of the target axis is at
fault.
(Origin return process error
occurred)
Check the situation of the error
occurred and error message, and
contact PFSC.
1530
Servo driver of the target axis
is at fault.
(Exclusive process error
occurred.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1531
Unwanted interrupt occurred
during positioning of X/Y
axes.
(Position interrupt error
occurred.)
1) Restart the machine.
2) If the error persists, contact PFSC.
1540
2-1-4-27
NPM–W2 EJM7DE-MB-02-1T-00
Data Set Command Not
Issued Error
Write EEPROM Error
Servo Ready Off
Completion Error Interrupt
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Unwanted interrupt occurred
during positioning of X/Y
axes.
(Completion interrupt error
occurred)
1) Restart the machine.
2) If the error persists, contact PFSC.
1542
Axis movement failed
because it was attempted
without the communication
with the servo amplifier
established.
(Servo ready OFF error
occurred.)
Restart the machine.If the error
persists even after the machine is
restarted, contact PFSC.
1543
Wiring between the main
controller and servo amplifier
may be broken.
(Writing to EEPROM in servo
amplifier failed to finish
properly.)
Make sure the wiring between the
main controller and servo amplifier
is not broken.
1545
Improper procedure was
taken in software processing.
(Axis movement failed due to
incorrect data of the
applicable axis (mismatch of
data combination).)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1546
2-1-4-28
NPM–W2 EJM7DE-MB-02-1T-00
Emergency Stop
Deceleration Error
Error Deceleration Error
Acceleration Command
Error
Speed Command Error
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
15
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Axis movement failed
because of zero set for the
axis speed.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1550
Improper procedure was
taken in software processing.
(Axis movement failed
because of zero set for the
axis acceleration.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1557
Improper procedure was
taken in software processing.
(Axis movement failed
because of zero set for the
axis deceleration for error
stop.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1558
Improper procedure was
taken in software processing.
(Axis movement failed
because of zero set for the
axis deceleration for
emergency stop.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1559
2-1-4-29