N7201A618E00_0309.pdf - 第245页

NPM–W 2 EJM7DE-MB-02 -1T-00 IspBox MainSys Abnormal PCB Support Holder Down Error PCB Suppor t Holder Up Error Solutions to errors Error Code Error Message Cause Inspection and Solution PCB s upport holder failed to rise…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Driver Alarm:
Power Voltage
Abnormality
Other Error
(Driver)
Action Undefined Error
Support Pin Interfere Error
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
38
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Support pin positions are
not proper for the PCB size.
2) Sensor is blocked due to
foreign body.
(Support pin detected during
conveyor width
adjustment.)
Take any of the following measures:
1) Check the PCB size and
positions of the support pins.
2) Remove any foreign body.If the
error persists, contact PFSC.
1858
Improper procedure was
taken in software processing.
(Action undefined error
occurred.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1859
Error with unanalyzable
cause occurred on the driver.
(Other error (driver)
occurred.)
Turn OFF power once and restart
the machine. If the error persists,
contact PFSC.
1860
Power voltage dropped or
the driver may be at fault.
(Driver alarm detected.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1861
2-1-4-75
NPM–W2 EJM7DE-MB-02-1T-00
IspBox MainSys Abnormal
PCB Support Holder
Down Error
PCB Support Holder Up
Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
PCB support holder failed to
rise within the prescribed
time.
(Error occurred in the PCB
support holder.)
1) Check the up/down of the PCB
support holder via the Output
confirm screen.
2) On the Input confirm screen,
check the condition of the
upper/lower limit sensors of PCB
support holder.
1862
PCB support holder failed to
lower within the prescribed
time.
(Error occurred in the PCB
support holder.)
1) Check the up/down of the PCB
support holder via the Output
confirm screen.
2) On the Input confirm screen,
check the condition of the
upper/lower limit sensors of PCB
support holder.
1864
Improper procedure was
taken in software processing.
(Inspection box software
failure occurred.)
Restart the machine. If the error
persists, contact PFSC.
1866
2-1-4-76
NPM–W2 EJM7DE-MB-02-1T-00
IspBox MainSys
Inspection result use
memory ensure error
IspBox MainSys
Production data Read
unfinished error
IspBox MainSys Machine
command Undefined error
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
39
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Improper procedure was
taken in software
processing.
2) Mismatch of the software
version between the
machine and the inspection
box.
(Undefined command
notified from machine to
inspection box.)
Take any of the following measures:
1) Restart the machine. If the error
persists, contact PFSC.
2) If the error occurred after
upgrade, check the situation of the
error occurred and error message,
and contact PFSC.
1867
Improper procedure was
taken in software processing.
(Inspection box has not
loaded production data.)
Restart the machine. If the error
persists, contact PFSC.
1868
Improper procedure was
taken in software processing.
(Failed to secure memory for
saving inspection results.)
Restart the machine. If the error
persists, contact PFSC.
1869
2-1-4-77