N7201A618E00_0309.pdf - 第117页
NPM–W 2 EJM7DE-MB-02 -1T-00 non-collation (verification2) PartsTopSideR ecCorrLim Over Nzl Height Last Val Diff Err Solutions to errors Error Code Error Message Cause Inspection and Solution The difference is over 0.1mm …

NPM–W2 EJM7DE-MB-02-1T-00
PrePickup Insp comm err
(ISS)
PrePickup Insp comm err
(LNB)
PrePickup Insp Error
Error
Message
Troubleshooting
2-1-3
Single stop error 24
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1)Parts direction is wrong.
2)Different parts is set.
3)The recognition data of
pre-pickup inspection is
wrong.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1)Please set correct direction.
2)Please set correct parts.
3)Please modify recognition data of
pre-pickup inspection
40467
The communication state is
abnormal between MC and
LNB.
(Single stop error occurred.)
Take any of the following measures:
1)Please confirm the
communication state between MC
and LNB.
2)Please confirm state or setting of
LNB.
40468
The communication state is
abnormal between LNB and
ISS(Inspection Server
Software).
(Single stop error occurred.)
Take any of the following measures:
1)Please confirm the
communication state between LNB
and ISS.
2)Please confirm state or setting of
ISS.
40469
2-1-3-46

NPM–W2 EJM7DE-MB-02-1T-00
non-collation
(verification2)
PartsTopSideRecCorrLim
Over
Nzl Height Last Val Diff
Err
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
The difference is over 0.1mm
compared to the last
measure result.
(Single stop error occurred.)
Check the mounting status of the
nozzle.Make sure that there is no
foreign body on the lens of the parts
recognition camera.Calibrate origin
offset Z-axis and multi recognition
camera offset.
40470
The offset position of
recognition object from parts
center is over the limit.
(Single stop error occurred.)
Please confirm if the following items
of head camera recognition
correction mount parameter are
set correctly in DGS.
1)The offset position of recognition
object from parts center
2)Limit
40471
Feeder which has been
pulled out and inserted^ but
has not executed verification
has been detected when
running starts.
(Single stop error occurred.)
Please start the production after
executing verification.
40472
2-1-3-47

NPM–W2 EJM7DE-MB-02-1T-00
Parts Recognition Error
Parts Recognition Error
Error
Message
Troubleshooting
2-1-3
Single stop error 25
Error Code
Error Message
Cause Inspection and Solution
Mismatch occurred in the
internal processing of
recognition function.Error
occurred in the parameter
area in the recognition
processing.
(Recognition error - Invalid
image processing
parameter )
Take any of the following measures:
1) Check the connection of
camera/sensor and lighting
units.Connected units can be
checked on the unit information
check screen.
2) Send the recognition data and
image detail data to PFSC.
43001
Mismatch occurred in the
internal processing of
recognition function.Error
occurred in the parameter
area in the recognition
processing.
(Recognition error - Invalid
image processing
parameter )
Take any of the following measures:
1) Check the connection of
camera/sensor and lighting
units.Connected units can be
checked on the unit information
check screen.
2) Send the recognition data and
image detail data to PFSC.
43002
2-1-3-48