N7201A618E00_0309.pdf - 第74页
NPM–W 2 EJM7DE-MB-02 -1T-00 Feeder Error Rate Over Bad Nozzle Rate Over Error Message Troubleshooting 2-1-3 Sing le stop er r o r 3 Error Code Error Message Cause Inspection and Solution No. of bad nozzles has exceeded t…

NPM–W2 EJM7DE-MB-02-1T-00
Bad Nozzle Detect
Part Mount Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Component was carried
back without mounting it.
2) Nozzle or filter is clogged
with dust or dirt.
3) Sensor may be at fault.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Remove the remaining
components from the nozzles and
restart the machine.
2) Clean the nozzle and filter.
3) Choose [Machine] - [Adjust] -
[Head] - [Vac output check] and if
any problem is found, contact
PFSC.
40309
Pickup or recognition error
occurs frequently at a
specific nozzle.
(Single stop error occurred.)
Choose [Machine] - [Set] - [Head] -
[Bad head] and identify the cause
(pickup error or recognition error).
Then perform appropriate
maintenance.
40310
2-1-3-3

NPM–W2 EJM7DE-MB-02-1T-00
Feeder Error Rate Over
Bad Nozzle Rate Over
Error
Message
Troubleshooting
2-1-3
Single stop error 3
Error Code
Error Message
Cause Inspection and Solution
No. of bad nozzles has
exceeded the preset count.
(Single stop error occurred.)
Take any of the following measures:
1) Choose [Machine] - [Set] - [Head]
- [Action Parameter] and make
sure the judgment value is correct.
2) Choose [Machine] - [Set] - [Head]
- [Bad head] and identify the cause
(pickup error or recognition error).
Then perform appropriate
maintenance and reset the setting
of bad nozzles.
40311
Pickup error rate for the
feeder has exceeded the
setting value.
(Single stop error occurred.)
Take any of the following measures:
1) Make sure the tape is not
jammed.
2) Make sure the parameters of the
component data are set properly.
40312
2-1-3-4

NPM–W2 EJM7DE-MB-02-1T-00
Conveyor Width Adj. Err
PCB Transfer Error
PCB Recognition Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Recognition mark is out of
camera's view.
2) Recognition error
occurred due to dirt on PCB.
3) PCB recognition
coordinates are incorrect.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Using the inching function, move
the camera to the recognition mark
position and press the Re-
recognize button.
2) After cleaning the recognition
camera and PCB, press the Re-
recognize button. If the recognition
error occurs again, move the
camera to the recognition mark
position with the Pass button or
inching function and press the
Manual set button. [Pass]: Pass
the PCB.[Manual set]: Save the
inching amount as the offset.
3) Choose [Production data] -
[Correct] - [PCB] - [PCB recog.]
and enter the correct PCB
recognition coordinates.
40313
PCB failed to be transferred
properly.
(Single stop error occurred.)
Check inside the machine and
remove the PCB.
40314
Width adjustment is disabled
because of the PCB on the
conveyor.
(Single stop error occurred.)
Remove the PCB.
40315
2-1-3-5