N7201A618E00_0309.pdf - 第99页

NPM–W 2 EJM7DE-MB-02 -1T-00 Head Error Rate Stop Feeder Error Rate Stop No Feeder Cover Solutions to errors Error Code Error Message Cause Inspection and Solution Operation wa s attempted without attaching th e feeder co…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Pst Prc Adjcnt Safe Unit
Err
Pre Prc Adjcnt Safe Unit
Err
Regular Check Error
Error
Message
Troubleshooting
2-1-3
Single stop error 15
Error Code
Error Message
Cause Inspection and Solution
Component information
written into feeder memory
for regular check and
scanned reel barcode
information not matched.
(Single stop error occurred.)
Read the correct reel barcode.
40390
1) Foreign body found at the
transfer opening.
2) Feeder cover not attached.
3) Emergency stop switch of
the adjoining machine has
been pressed.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Remove any foreign body from
the transfer opening.
2) Attach the feeder cover.
3) Release the emergency stop
status of the adjoining machine.
40391
1) Foreign body found at the
transfer opening.
2)Feeder cover not attached.
3) Emergency stop switch of
the adjoining machine has
been pressed.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Remove any foreign body from
the transfer opening.
2) Attach the feeder cover.
3)Release the emergency stop
status of the adjoining machine.
40392
2-1-3-28
NPM–W2 EJM7DE-MB-02-1T-00
Head Error Rate Stop
Feeder Error Rate Stop
No Feeder Cover
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Operation was attempted
without attaching the feeder
cover.
(Single stop error occurred.)
Take any of the following measures:
1) Attach the feeder cover.
2) If the error persists even after the
feeder cover is attached, the
connection with the connector of
the feeder cover may not be
detected. Choose [Machine] -
[Adjust] - [All] - [Input confirm] and
check the connection of the feeder
cover.
40393
Pickup errors and/or
recognition errors have
occurred beyond the bad
feeder error rate set in action
parameters.
(Single stop error occurred.)
Check the condition of the feeder
and clean it if necessary.
40394
Pickup errors and/or
recognition errors have
occurred beyond the bad
head error rate set in action
parameters.
(Single stop error occurred.)
Check the condition of the head and
clean it if necessary.
40395
2-1-3-29
NPM–W2 EJM7DE-MB-02-1T-00
Stamp Parts Drop Error
Stamp Time Over Error
Stamp Empty Error
Nozzle Error Rate Stop
Error
Message
Troubleshooting
2-1-3
Single stop error 16
Error Code
Error Message
Cause Inspection and Solution
Pickup errors and/or
recognition errors have
occurred beyond the bad
nozzle error rate set in action
parameters.
(Single stop error occurred.)
Check the condition of the nozzle
and clean it if necessary.
40396
Transcript material has run
out.
(Single stop error occurred.)
Supply the transcript material.
40397
Transcript time was
exceeded.
(Single stop error occurred.)
Supply the transcript material.
40398
Component may have
dropped in the transcript unit.
(Single stop error occurred.)
Check the transcript unit and
remove any component.
40399
2-1-3-30