NPM–W 2 EJM7DE-MB-02 -1T-00 Pick up error (Rec og.) Shape of Parts e rr (Rec og.) Part Thick range ov (Rec og.) Part Thick det err (Rec og.) Solutions to errors Error Code Error Message Cause Inspection and Solution Mess…

NPM–W2 EJM7DE-MB-02-1T-00
Momentary Power OFF
Air Pressure Error
Tray parts remain load
error
Error
Message
Troubleshooting
2-1-3
Single stop error 22
Error Code
Error Message
Cause Inspection and Solution
Fail to load the parts remain
from tray pallet memory.
(Single stop error occurred.)
1.Please confirm if the tray pallet is
exist in tray pallet arrange and load
position.2.Please confirm if it can
write and load in applicable tray
pallet memory.3.Please contact
PFSC when above1.2confirm result
problem is nothing.
40437
Abnormal air pressure.
(Single stop error occurred.)
Take any of the following measures:
1)Please adjust the regulator when
the supplied air pressure is low.
Please refer to the operating
instruction(Maintenance
articles)about setting pressure.
2)If the air pressure detection
setting(Low limit setting) is too
high, error occurs. Please set the
air pressure detection value to
0.4MPa.
40450
Power supply may have
been stopped momentarily
due to power failure.
(Single stop error occurred.)
Check the voltage of the power
supply in the plant. Turn ON the
power and resume production. If the
error persists, contact PF
40451
2-1-3-42

NPM–W2 EJM7DE-MB-02-1T-00
Pick up error
(Recog.)
Shape of Parts err
(Recog.)
Part Thick range ov
(Recog.)
Part Thick det err
(Recog.)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Messure result is out of
effective range.
(Single stop error occurred.)
Make sure the component is set
properly and correct values of the
component data (component
dimensions, etc.) are set.
40452
Component thickness
measurement result is
beyond the threshold value of
thickness tolerance.
(Single stop error occurred.)
Check the upper and lower limits of
the thickness tolerance in the
mounting condition data of
component data.
40453
Invalid component pickup
status.
(Single stop error occurred.)
Check the component data
(component dimensions, etc.).Check
the pickup condition.
40454
Any of the following causes
is likely:
1) Incorrect component data
height
2) Improper component feed.
3) Incorrect feeder position.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Correct the component data.
2) Replace the tape feeder.
3) Choose [Production data] -
[Teach] - [Feeder] - [Pickup
position] and perform teaching of
the component pickup position.
40455
2-1-3-43

NPM–W2 EJM7DE-MB-02-1T-00
Nzl Point Abnormal Error
Nzl Height Range Ov
(Recog.)
Nzl Height Det Err
(Recog.)
Tape unset error
Tape off detect error
Error
Message
Troubleshooting
2-1-3
Single stop error 23
Error Code
Error Message
Cause Inspection and Solution
The tape may be dropped out.
(Single stop error occurred.)
Check if the tape is inserted
correctly.
40456
The tape is not set.
(Single stop error occurred.)
Check if the tape is inserted
correctly.
40457
Measurement result is out of
output value.
(Single stop error occurred.)
Check the mounting status of the
nozzle.Make sure that there is no
foreign body on the lens of the parts
recognition camera.Calibrate origin
offset Z-axis and multi recognition
camera offset.
40458
Difference between nozzle
detection result and nozzle
length exceeded the range of
-0.3mm~0.4mm.
(Single stop error occurred.)
Check the nozzle length.Calibrate
origin offset Z-axis and multi
recognition camera offset.
40459
Tip of the nozzle is not planar.
(Single stop error occurred.)
Check the tip of the nozzle and
clean it. Replace the faulty nozzle.
40460