N7201A618E00_0309.pdf - 第81页

NPM–W 2 EJM7DE-MB-02 -1T-00 Pickup Pos Reco g Error Nozz le Change Err or Solutions to errors Error Code Error Message Cause Inspection and Solution Any of the following causes is likely: 1) Improper shutter action at no…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Nozzle Recognition Error
Nozzle Fall
Error
Message
Troubleshooting
2-1-3
Single stop error 6
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Nozzle came off during
pickup or mounting.
2) Filter is clogged.
3) Sensor may be at fault.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Check the nozzle and attach it if it
came off.
2) Clean the filter.
3) Choose [Machine] - [Adjust] -
[Head] - [Vac output check] and if
any problem is found, contact
PFSC.
40329
Recognition error occurred
due to dirty mark^ etc.
(Single stop error occurred.)
Check if the time-lapse change
calibration mark is not dirty. Clean
the mark if dirty.
40330
2-1-3-10
NPM–W2 EJM7DE-MB-02-1T-00
Pickup Pos Recog Error
Nozzle Change Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Improper shutter action at
nozzle changer
2) Improper cylinder action
3) Deformed or bent nozzle
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Choose [Machine] - [Adjust] -
[Head] - [Nozzle exchange] and
open/close the nozzle changer.
Check for proper movement. If
stopped or caught on the way,
perform cleaning.
2) Replace the cylinder.
3) Replace the nozzle.
40331
Component is out of
camera's view.
(Single stop error occurred.)
Take measures in the following
order.
1) Move the camera to the center
position of the component using
the inching function and press the
[Recognize] button.
2) If the recognition error occurs
again, move the camera to the
center position of the component
using the inching function and
press the [Manual set]
button.[Manual set]: Save the
inching amount as the offset.
40332
2-1-3-11
NPM–W2 EJM7DE-MB-02-1T-00
Serial Calib Recog Error
Mount Pos Recog Error
Error
Message
Troubleshooting
2-1-3
Single stop error 7
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1)Recognition mark is out of
camera's view.
2)Recognition error occurred
due to dirt on PCB.
3) Mounting point recognition
coordinates are incorrect.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Move the camera to the
recognition mark position using the
inching function and press the [Re-
recognize] button.
2) After cleaning the recognition
camera and PCB, press the [Re-
recognize] button. If the
recognition error occurs again,
press the [No Recognition] or
[Pass] button.[No Recognition]:
Proceeds to the next process
without performing
recognition[Pass]: Pass the PCB.
3) Choose [Production data] -
[Correct] - [Mount] and enter the
mounting point recognition
coordinates correctly.
40333
Mark recognition error
occurred in time-lapse
change calibration.
(Single stop error occurred.)
Take any of the following measures:
1) Make sure the mark surface at
calibration cylinder is not dirty.
Perform cleaning if found dirty
2) Make sure the head camera light
is lit properly. If not lit, contact
PFSC.
40334
2-1-3-12