N7201A618E00_0309.pdf - 第159页

NPM–W 2 EJM7DE-MB-02 -1T-00 PCB Carry out Error PCB Carry in Error Inside Work Memory Error Solutions to errors Error Code Error Message Cause Inspection and Solution Internal pro cessing erro r occurred durin g shot rec…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Rcg Prm Err
(Standard Area)
Recog Param Error
(Area Rate)
Rcg Prm Err
(Area Max Limit)
Rcg Prm Err
(Area Min Limit)
Error
Message
Troubleshooting
2-1-3
Single stop error 45
Error Code
Error Message
Cause Inspection and Solution
Invalid value set in allowable
lower limit of total area in
priming shot recognition data.
(Recognition parameter error
(allowable area lower limit)
occurred.)
Check the allowable lower limit
value of the total area. If the error
persists, contact PFSC.
43520
Invalid value set in allowable
upper limit of total area in
priming shot recognition data.
(Recognition parameter error
(allowable total area upper
limit occurred.)
Check the allowable upper limit
value of the total area. If the error
persists, contact PFSC.
43521
Invalid value set in allowable
large/small area ratio in
priming shot recognition data.
(Recognition parameter error
(large/small area ratio
occurred.)
Check the allowable large/small
area ratio. If the error persists,
contact PFSC.
43522
Invalid value set in reference
area in priming shot
recognition data.
(Recognition parameter error
(reference area) occurred.)
Check the value of the reference
area. If the error persists, contact
PFSC.
43523
2-1-3-88
NPM–W2 EJM7DE-MB-02-1T-00
PCB Carry out Error
PCB Carry in Error
Inside Work Memory Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Internal processing error
occurred during shot
recognition.
(Internal work memory
failure)
Check the situation of the error
occurred and error message, and
contact PFSC.
43524
Timeout occurred while
loading PCB.
(PCB loading error
occurred.)
Take any of the following measures:
1) Check the PCB on the conveyor
and condition of the PCB sensor.
2) Check the conveyor width.
44000
Timeout occurred while
unloading PCB.
(PCB unloading error
occurred.)
Take any of the following measures:
1) Check the PCB on the conveyor
and condition of the PCB sensor.
2) Check the conveyor width.
44001
2-1-3-89
NPM–W2 EJM7DE-MB-02-1T-00
PCB existed Error
Post proc ReqOFF time
out err
Sens err after PCB carry
out
Error
Message
Troubleshooting
2-1-3
Single stop error 46
Error Code
Error Message
Cause Inspection and Solution
Stop position sensor was ON
after unloading PCB.
(Error occurred in sensor
after unloading PCB.)
Take any of the following measures:
1) Check the PCB on the conveyor
and condition of the PCB sensor.
2) Check the conveyor width.
44002
PCB request signal from
next process machine after
unloading PCB failed to turn
OFF within the prescribed
time.
(Timeout error occurred
while waiting for request
OFF from next process
machine.)
Take any of the following measures:
1) Check the PCB on the conveyor
and condition of the PCB sensor.
2) Check the setting value of PCB
eject waiting time (request OFF).
44003
PCB stop position sensor
was ON before loading PCB.
(PCB presence detected
when loading PCB.)
Check the PCB on the conveyor and
condition of the PCB sensor.
44004
2-1-3-90