N7201A618E00_0309.pdf - 第45页

NPM–W 2 EJM7DE-MB-02 -1T-00 12-Nozzle Head θ PCB Fuse Disconne ction 12-Nozzle Head θ PCB Temper ature Erro r 12-Nozzle Head θ PCB Voltage Error 12-Nozzle Head Z PCB Fuse Disconne ction 12-Nozzle Head Z PCB Temper ature …

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
12-nozzle head Z PCB
Voltage Error
Unknown Unit Detection
(Option lamp)
Unknown Unit Detection
(Height sensor)
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 10
Error Code
Error Message
Cause Inspection and Solution
Height measurement sensor
cannot be detected.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Make sure the height
measurement sensor is set
properly.
2) Choose [Machine] - [Information]
- [PnP] - [List] and make sure the
unit is installed to the height
measurement sensor. If the error
persists, contact PFSC.
40047
Option light cannot be
detected.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Make sure the option light is set
properly.
2) Choose [Machine] - [Information]
- [PnP] - [List] and check that the
option light is installed. If the error
persists, contact PFSC.
40048
Voltage at the 12-nozzle
mount head Z-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40049
2-1-2-19
NPM–W2 EJM7DE-MB-02-1T-00
12-Nozzle HeadθPCB
Fuse Disconnection
12-Nozzle HeadθPCB
Temperature Error
12-Nozzle Head θPCB
Voltage Error
12-Nozzle Head Z PCB
Fuse Disconnection
12-Nozzle Head Z PCB
Temperature Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
CPU temperature at the 12-
nozzle mount head Z-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40050
Fuse of the 12-nozzle mount
head Z-axis control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40051
Voltage at the 12-nozzle
mount head θ-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40052
CPU temperature at the 12-
nozzle mount head θ-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40053
Fuse of the 12-nozzle mount
head θ-axis control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40054
2-1-2-20
NPM–W2 EJM7DE-MB-02-1T-00
8-Nozzle Head θ PCB
Temperature Error
8-Nozzle Head θ PCB
Voltage Error
8-Nozzle Head Z PCB
Fuse Disconnection
8-Nozzle Head Z PCB
Temperature Error
8-Nozzle Head Z PCB
Voltage Error
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 11
Error Code
Error Message
Cause Inspection and Solution
Voltage at the 8-nozzle
mount head Z-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40055
CPU temperature at the 8-
nozzle mount head Z-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40056
Fuse of the 8-nozzle mount
head Z-axis control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40057
Voltage at the 8-nozzle
mount head θ-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40058
CPU temperature at the 8-
nozzle mount head θ-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40059
2-1-2-21