NPM–W 2 EJM7DE-MB-02 -1T-00 Communication : (Common Slave): Parameter Error Communication : (Common Slave): Command Error Communication : ROM Update Count Error Communication : Specified File Close Error Communication : …

NPM–W2 EJM7DE-MB-02-1T-00
Communication:
Specified File Size Acquire
Error
Communication:
Specified File Open Error
Communication:
Status Communication
Error
Communication:
Status Communication
Stopping Error
Communication:
Completion Error
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
32
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Transmission command not
executed properly.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1749
Improper procedure was
taken in software processing.
(Function to obtain status
was called while status
communication was
stopped.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1750
Improper procedure was
taken in software processing.
(Error occurred in status
communication.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1751
Improper procedure was
taken in software processing.
(Cannot open ROMless file.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1752
Improper procedure was
taken in software processing.
(Improper ROMless file size.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1755
2-1-4-63

NPM–W2 EJM7DE-MB-02-1T-00
Communication:
(Common Slave):
Parameter Error
Communication:
(Common Slave):
Command Error
Communication:
ROM Update Count Error
Communication:
Specified File Close Error
Communication:
Specified File Size Read
Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Cannot read the ROMless
file size.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1756
Improper procedure was
taken in software processing.
(Failed to close ROMless
file.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1757
Writing to FROM exceeded
the limit.
(ROMless count exceeded
the specified write count.)
Contact PFSC.
1758
Improper procedure was
taken in software processing.
(Undefined command
issued.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1760
Improper procedure was
taken in software processing.
e.g.: 2 has been set although
available parameter is 0 or 1.
(Invalid parameter setting.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1762
2-1-4-64

NPM–W2 EJM7DE-MB-02-1T-00
Feeder Number Set Error
NG Eject Conveyer Action
Timeout
Communication:
(Common Slave):
Undefined Error
Communication:
(Common Slave):
System Section Error
Communication:
(Common Slave):
Communication Error
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
33
Error Code
Error Message
Cause Inspection and Solution
Check sum error occurred in
the communication data from
the head or feeder cart to the
host.
(Communication error
occurred.)
Clean the drawer connectors for
connecting modules, and check the
wiring connected to them. If the
error persists, contact PFSC.
1763
Embedded software for each
board may be damaged.
(Check sum error occurred in
ROMless file.)
Read the ROMless file again and
restart production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1764
Improper procedure was
taken in software processing.
(Undefined error occurred.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1765
NG eject conveyor failed to
finish operation within the
prescribed time.
(NG eject conveyor failed to
operate properly.)
Check the NG eject conveyor for
proper movement using the
switches.If not, contact PFSC.
1766
Improper procedure was
taken in software processing.
(Feeder number error
occurred.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1768
2-1-4-65