N7201A618E00_0309.pdf - 第49页

NPM–W 2 EJM7DE-MB-02 -1T-00 NCIO Bo ard Temperatur e Error Inspection H ead PCB 24 V Fuse Disconne ction Inspection H ead PCB 5V Fuse Disconne ction Inspection H ead PCB Light 24 Fuse Disco nnection Inspection H ead PCB …

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
Dispense Head θ Screw
PCB Fuse Disconnection
Dispense Head θ Screw
PCB Temperature Error
Dispense Head θ Screw
PCB Voltage Error
Dispense Head Z PCB
Fuse Disconnection
Dispense Head Z PCB
Temperature Error
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 12
Error Code
Error Message
Cause Inspection and Solution
CPU temperature at the 2-
nozzle dispense head Z-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Contact PFSC.
40065
Fuse of the 2-nozzle
dispense head Z-axis control
board has blown.
(Self-diagnosis error
occurred.)
Contact PFSC.
40066
Voltage at the 2-nozzle
dispense head θ-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Make sure there is nothing wrong
with electrical wiring.
40067
CPU temperature at the 2-
nozzle dispense head θ-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Contact PFSC.
40068
Fuse of the 2-nozzle
dispense head θ-axis control
board has blown.
(Self-diagnosis error
occurred.)
Contact PFSC.
40069
2-1-2-23
NPM–W2 EJM7DE-MB-02-1T-00
NCIO Board Temperature
Error
Inspection Head PCB 24V
Fuse Disconnection
Inspection Head PCB 5V
Fuse Disconnection
Inspection Head PCB
Light 24 Fuse
Disconnection
Inspection Head PCB
Temperature Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Voltage at the inspection
head light control board has
dropped abnormally.
(Self-diagnosis error
occurred.)
Make sure there is nothing wrong
with electrical wiring.
40070
24V fuse of the inspection
head light control board has
blown.
(Self-diagnosis error
occurred.)
Contact PFSC.
40071
External 5V fuse of the
inspection head light control
board has blown.
(Self-diagnosis error
occurred.)
Contact PFSC.
40072
External 24V fuse of the
inspection head light control
board has blown.
(Self-diagnosis error
occurred.)
Contact PFSC.
40073
CPU temperature at the
NCIO board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40074
2-1-2-24
NPM–W2 EJM7DE-MB-02-1T-00
H-Camera Board External
5V Fuse Disconnection
H-Camera Board Light
24V Fuse Disconnection
H-Camera Light Control
Board Temperature Error
ILK Board Temperature
Error
ILK Board Voltage Error
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 13
Error Code
Error Message
Cause Inspection and Solution
Voltage at the ILK board has
dropped abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40075
CPU temperature at the ILK
board has exceeded the
setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40076
CPU temperature at the head
camera light control board
has exceeded the setting
value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40077
24V fuse of the head camera
light control board has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40078
External 5V fuse of the head
camera light control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40079
2-1-2-25