NPM–W 2 EJM7DE-MB-02 -1T-00 Tray A Control Board Fuse Disco nnection Tray A Control Board Temper ature Erro r Tray A Control Board Voltage Error L-Camera Board External 24V Fus e Disco nnection Error Message Troubleshoot…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
L-Camera Board External
5V Fuse Disconnection
L-Camera Board Light 24V
Fuse Disconnection
L-Camera Board
Temperature Error
H-Camera Board PCB
Warpage Sensor Fuse
Disconnection
H-Camera Board External
24V Fuse Disconnection
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
External 24V fuse of the
head camera light control
board has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40080
PCB warp sensor fuse of the
head camera light control
board has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40081
CPU temperature at the line
camera light control board
has exceeded the setting
value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40082
24V fuse of the line camera
light control board has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40083
External 5V fuse of the line
camera light control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40084
2-1-2-26
NPM–W2 EJM7DE-MB-02-1T-00
Tray A Control Board Fuse
Disconnection
Tray A Control Board
Temperature Error
Tray A Control Board
Voltage Error
L-Camera Board External
24V Fuse Disconnection
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 14
Error Code
Error Message
Cause Inspection and Solution
External 24V fuse of the line
camera light control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40085
Voltage at the tray control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40086
CPU temperature at the tray
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40087
Fuse of the tray control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40088
2-1-2-27
NPM–W2 EJM7DE-MB-02-1T-00
P9Case Temperature
Error
P9Case Fan Error
P9 Power Fan Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Fan of the P9 controller
power stopped.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Check the fan for any
interference with wiring, etc.
2) Make sure there is no
disconnected wire.
40089
Fan of the P9 controller case
stopped.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Check the fan for any
interference with wiring, etc.
2) Make sure there is no
disconnected wire.
40090
Inside temperature of the P9
controller case is higher than
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40091