N7201A618E00_0309.pdf - 第163页

NPM–W 2 EJM7DE-MB-02 -1T-00 LNB Command Send Error PCB Info Confirm Error Solutions to errors Error Code Error Message Cause Inspection and Solution Failed to check PCB information du ring PCB transfer. (Error occurred d…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
PCB Info Communication
Error
PCB Info transfer Error
Error
Message
Troubleshooting
2-1-3
Single stop error 47
Error Code
Error Message
Cause Inspection and Solution
Error occurred while
transferring PCB information
during PCB transfer.
(Error occurred during
transfer of PCB information.)
Take any of the following measures:
1) Check the position of PCB on the
conveyor.
2) Check the setting of
communication between machines.
3) Check the situation of the error
occurred and contact PFSC.
44008
Timeout occurred while
waiting for transferring PCB
information during PCB
unloading.
(Error occurred in
communication of PCB
information.)
Take any of the following measures:
1) Check the position of PCB on the
conveyor.
2) Check the setting of
communication between machines.
3) Check the situation of the error
occurred and contact PFSC.
44009
2-1-3-92
NPM–W2 EJM7DE-MB-02-1T-00
LNB Command Send
Error
PCB Info Confirm Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Failed to check PCB
information during PCB
transfer.
(Error occurred during PCB
information check.)
Take any of the following measures:
1) Check the position of PCB on the
conveyor.
2) Check the setting of
communication between machines.
3) Check the situation of the error
occurred and contact PFSC.
44010
Transmission error occurred
while requesting for reading
external PCB barcode.
(Error occurred in
transferring command to
LNB.)
Take any of the following measures:
1) Check the communication
between the LNB and machine.
2) Check the setting of
communication between machines.
3) Check the situation of the error
occurred and contact PFSC.
44011
2-1-3-93
NPM–W2 EJM7DE-MB-02-1T-00
LNB Command Receive
Timeout
Upper System restriction
Err
Error
Message
Troubleshooting
2-1-3
Single stop error 48
Error Code
Error Message
Cause Inspection and Solution
Reception error occurred
while checking for reading of
external PCB barcode.
(Error occurred in receiving
command from LNB.)
Take any of the following measures:
1) Check the communication
between the LNB and machine.
2) Check the setting of
communication between machines.
3) Check the situation of the error
occurred and contact PFSC.
44012
Timeout occurred while
waiting for reading external
PCB barcode.
(Timeout occurred in receipt
of command from LNB.)
Take any of the following measures:
1) Check the communication
between the LNB and machine.
2) Check the setting of
communication between machines.
3) Check the situation of the error
occurred and contact PFSC.
44013
2-1-3-94