N7201A618E00_0309.pdf - 第226页
NPM–W 2 EJM7DE-MB-02 -1T-00 Timeout Error Command processing error Over Current Anomaly (R) Encoder Dis connect Anomaly (R) Error Message Troubleshooting 2-1-4 Emer genc y stop er r or s 29 Error Code Error Message Cause…

NPM–W2 EJM7DE-MB-02-1T-00
Overload Anomaly
(R)
Over Current Anomaly
(L)
Encoder Disconnect
Anomaly
(L)
Overload Anomaly
(L)
Origin Return Abnormality
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Origin return failed to be
completed within the
prescribed time and timeout
occurred.
(Head axis did not properly
return to origin. )
Check the situation of the error
occurred and error message, and
contact PFSC.
1717
Positional deviation with
power ON or integrated
current is beyond the
specified value.
(Head movement stopped
due to overload.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1718
Invalid motor encoder value.
(Head movement stopped.)
Check the connection between the
head motor and control board inside
the head and restart production.
Then, check the situation of the
error occurred and error message,
and contact PFSC.
1719
Current exceeding the
specified value has flown
during head movement.
(Abnormal voltage of current
was supplied to the head
motor.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1720
Positional deviation with
power ON or integrated
current is beyond the
specified value.
(Head movement stopped
due to overload.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1721
2-1-4-56

NPM–W2 EJM7DE-MB-02-1T-00
Timeout Error
Command processing
error
Over Current Anomaly
(R)
Encoder Disconnect
Anomaly
(R)
Error
Message
Troubleshooting
2-1-4
Emergency stop errors
29
Error Code
Error Message
Cause Inspection and Solution
Invalid motor encoder value.
(Head movement stopped.)
Check the connection between the
head motor and control board inside
the head and restart production.
Then, check the situation of the
error occurred and error message,
and contact PFSC.
1722
Current exceeding the
specified value has flown
during head movement.
(Abnormal voltage of current
was supplied to the head
motor.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1723
Communication error
occurred between the driver
and host. Cable between the
head motor and driver may
be broken.
(Error occurred in command
processing.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1724
No response from the head
or feeder cart^ etc.
(Communication timeout
error occurred.)
Clean the drawer connectors for
connecting head and feeder cart,
and check the wiring to be
connected to them. If the error
persists, contact PFSC.
1725
2-1-4-57

NPM–W2 EJM7DE-MB-02-1T-00
Communication:
FROM Delete Error
Communication Error
Check Sum Error
Head No. Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Error occurred in
communication with the head
or feeder cart^ etc.
(Communication failure)
Clean the drawer connectors for
connecting head and feeder cart,
and check the wiring to be
connected to them. If the error
persists, contact PFSC.
1726
Check sum error occurred in
the communication data from
the head or feeder cart^ etc.
to the host.
(Communication error
occurred.)
Clean the drawer connectors for
connecting head and feeder cart,
and check the wiring to be
connected to them. If the error
persists, contact PFSC.
1727
Improper procedure was
taken in software processing.
(Communication error
occurred.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1728
Improper procedure was
taken in software processing.
(Failed to clear FROM.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1729
2-1-4-58