N7201A618E00_0309.pdf - 第71页

NPM–W 2 EJM7DE-MB-02 -1T-00 Part Pickup Error Stock Parts Empty Parts Empty Stop Parts Empty Occurs Parts Empty Warning Error Message Solutions to errors Troubleshooting 2-1-3 Sing le stop er r o r 1 Error Code Error Mes…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
PrePickup Insp comm err
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 23
Error Code
Error Message
Cause Inspection and Solution
The communication state is
abnormal among MC-LNB-
ISS(Inspection Server
Software).
(Self-diagnosis error
occurred.)
Take any of the following measures:
1)Please confirm the
communication state between MC
and LNB, LNB and ISS.
2)Please confirm state or setting of
LNB and ISS.
40157
2-1-2-45
NPM–W2 EJM7DE-MB-02-1T-00
Part Pickup Error
Stock Parts Empty
Parts Empty Stop
Parts Empty Occurs
Parts Empty Warning
Error
Message
Solutions to errors
Troubleshooting
2-1-3
Single stop error 1
Error Code
Error Message
Cause Inspection and Solution
Components are running
short.
(Single stop error occurred.)
Supply the components.
40302
Components have run out.
(Single stop error occurred.)
Supply the components.
40303
Components have run out.
(Single stop error occurred.)
Supply the components.
40304
Stocked components have
run out.
(Single stop error occurred.)
Supply the components.
40305
Any of the following causes
is likely:
1) Invalid component data
height.
2) Improper component feed.
3) Incorrect pickup position.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Correct the component data.
2) Replace the tape feeder.
3) Choose [Arrange] - [Parts
prepare] - [Feeder] - [Pickup
position] and perform teaching of
the component pickup position.
40306
2-1-3-1
NPM–W2 EJM7DE-MB-02-1T-00
Parts Standing Error
Parts Recognition Error
Error
Message
Troubleshooting
2-1-3
Single stop error 2
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Improper components are
set.
2) Incorrect component data
(component dimensions^
etc.)
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Set the correct components.
2) Check the component data
(component dimensions, etc.).
40307
Any of the following causes
is likely:
1) Improper components are
set.
2) Incorrect component data
(component dimensions^
etc.)
3) Component picked up
sideways.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Set the correct components.
2) Check the component data
(component dimensions, etc.).
3) Check the pickup condition.
40308
2-1-3-2