N7201A618E00_0309.pdf - 第57页

NPM–W 2 EJM7DE-MB-02 -1T-00 Pre Proc Adjacent Safety Device Error There is no feeder cover or tray feeder Solutions to errors Error Code Error Message Cause Inspection and Solution No feeder cover. Or tray feeder not ins…

100%1 / 338
NPM–W2 EJM7DE-MB-02-1T-00
No Changer unit
No Eject BOX
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 16
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Component ejection box
not set in position.
2) Nozzle wiping station
(only for dispense head)
has been set.
(Self-diagnosis error
occurred.)
Reset the component ejection box
properly.
40098
Nozzle changer not installed.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Install the changer corresponding
to the head.
2) If the error persists even after the
changer is installed, the
connection with the changer may
not be detected.Choose [Machine]
- [Adjust] - [All] - [Input confirm]
and check the connection of
changer.
40099
2-1-2-31
NPM–W2 EJM7DE-MB-02-1T-00
Pre Proc Adjacent Safety
Device Error
There is no feeder cover
or tray feeder
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
No feeder cover. Or tray
feeder not installed.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Attach the feeder cover when the
feeder cart is used.
2) When the tray feeder is used,
install the tray feeder and then
insert the key in the tray feeder
detection switch.
3) If the error persists, choose
[Machine] - [Adjust] - [All] - [Input
confirm] and check that the feeder
cover is attached and the tray
detection switch is connected.
40100
Any of the following causes
is likely:
1) Foreign body found at the
transfer opening.
2) Feeder cover not attached.
3) Emergency stop switch of
the adjoining machine has
been pressed.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Remove any foreign body from
the transfer opening.
2) Attach the feeder cover.
3) Reset the emergency stop status
of the adjoining machine.
40101
2-1-2-32
NPM–W2 EJM7DE-MB-02-1T-00
Head Move Error
Cancel Flag Error
Post Proc Adjacent Safety
Device Error
Error
Message
Troubleshooting
2-1-2
Self-diagnosis errors 17
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Foreign body found at the
transfer opening.
2) Feeder cover not attached.
3) Emergency stop switch of
the adjoining machine has
been pressed
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Remove any foreign body from
the transfer opening.
2) Attach the feeder cover.
3) Reset the emergency stop status
of the adjoining machine.
40102
Any of the following causes
is likely:
1) Cover switch is disabled.
2) Only the feeder cover
connector
connected/disconnected
without opening/closing the
cover.
(Self-diagnosis error
occurred.)
Take any of the following
measures:Open/close the cover and
restart the machine.If the trouble
persists even after the above steps,
the cover switch may be
broken.Contact PFSC.
40103
Head may interfere with the
mounted components on the
board.
(Self-diagnosis error
occurred.)
Move the head to the pickup position
by hand. In doing so, take care not
to interfere with the mounted
components
40104
2-1-2-33