sh030106u.pdf - 第147页
5. PARAMETE RS 5 - 2 5.1.1 Bas ic setting p arameters ([Pr. P A_ _ ]) No. Symbol Name Initial value Unit Operation mode Standard Full. Lin. D.D. PA01 **STY Operation mode 1000h PA02 **RE G Regenerative option 0000h PA03 …

5. PARAMETERS
5 - 1
5. PARAMETERS
CAUTION
Never make a drastic adjustment or change to the parameter values as doing so
will make the operation unstable.
Do not change the parameter settings as described below. Doing so may cause
an unexpected condition, such as failing to start up the servo amplifier.
Changing the values of the parameters for manufacturer setting
Setting a value out of the range
Changing the fixed values in the digits of a parameter
When you write parameters with the controller, make sure that the control axis No.
of the servo amplifier is set correctly. Otherwise, the parameter settings of another
axis may be written, possibly causing the servo amplifier to be an unexpected
condition.
POINT
When you connect the amplifier to a servo system controller, servo parameter
values of the servo system controller will be written to each parameter.
Setting may not be made to some parameters and their ranges depending on
the servo system controller model, servo amplifier software version, and MR
Configurator2 software version. For details, refer to the servo system controller
user's manual. Check the software version of the servo amplifier using MR
Configurator2.
5.1 Parameter list
POINT
The parameter whose symbol is preceded by * is enabled with the following
conditions:
*: After setting the parameter, cycle the power or reset the controller.
**: After setting the parameter, cycle the power.
Abbreviations of operation modes indicate the followings.
Standard: Semi closed loop system use of the rotary servo motor
Full.: Fully closed loop system use of the rotary servo motor
Lin.: Linear servo motor use
D.D.: Direct drive motor use
For servo amplifier with software version B3 or later, the parameter initial values
for the manufacturer setting are partially changed.
If using the MR-J4-_B-RJ servo amplifier with the DC power supply input, set
[Pr. PC20] to "_ _ _1".

5. PARAMETERS
5 - 2
5.1.1 Basic setting parameters ([Pr. PA_ _ ])
No. Symbol Name
Initial
value
Unit
Operation
mode
Standard
Full.
Lin.
D.D.
PA01 **STY Operation mode 1000h
PA02 **REG Regenerative option 0000h
PA03 *ABS Absolute position detection system 0000h
PA04 *AOP1 Function selection A-1 2000h
PA05 For manufacturer setting 10000
PA06 1
PA07 1
PA08 ATU Auto tuning mode 0001h
PA09 RSP Auto tuning response 16
PA10 INP In-position range 1600 [pulse]
PA11 For manufacturer setting 1000.0
PA12 1000.0
PA13 0000h
PA14 *POL Rotation direction selection/travel direction selection 0
PA15 *ENR Encoder output pulses 4000 [pulse/rev]
PA16 *ENR2 Encoder output pulses 2 1
PA17 **MSR Servo motor series setting 0000h
PA18 **MTY Servo motor type setting 0000h
PA19 *BLK Parameter writing inhibit 00ABh
PA20 *TDS Tough drive setting 0000h
PA21 *AOP3 Function selection A-3 0001h
PA22 **PCS Position control composition selection 0000h
PA23 DRAT Drive recorder arbitrary alarm trigger setting 0000h
PA24 AOP4 Function selection A-4 0000h
PA25 OTHOV One-touch tuning - Overshoot permissible level 0 [%]
PA26 *AOP5 Function selection A-5 0000h
PA27 For manufacturer setting 0000h
PA28 0000h
PA29 0000h
PA30 0000h
PA31 0000h
PA32 0000h

5. PARAMETERS
5 - 3
5.1.2 Gain/filter setting parameters ([Pr. PB_ _ ])
No. Symbol Name
Initial
value
Unit
Operation
mode
Standard
Full.
Lin.
D.D.
PB01 FILT Adaptive tuning mode (adaptive filter II) 0000h
PB02 VRFT
Vibration suppression control tuning mode (advanced vibration
suppression control II)
0000h
PB03 TFBGN Torque feedback loop gain 18000 [rad/s]
PB04 FFC Feed forward gain 0 [%]
PB05 For manufacturer setting 500
PB06 GD2 Load to motor inertia ratio/load to motor mass ratio 7.00 [Multiplier]
PB07 PG1 Model loop gain 15.0 [rad/s]
PB08 PG2 Position loop gain 37.0 [rad/s]
PB09 VG2 Speed loop gain 823 [rad/s]
PB10 VIC Speed integral compensation 33.7 [ms]
PB11 VDC Speed differential compensation 980
PB12 OVA Overshoot amount compensation 0 [%]
PB13 NH1 Machine resonance suppression filter 1 4500 [Hz]
PB14 NHQ1 Notch shape selection 1 0000h
PB15 NH2 Machine resonance suppression filter 2 4500 [Hz]
PB16 NHQ2 Notch shape selection 2 0000h
PB17 NHF Shaft resonance suppression filter 0000h
PB18 LPF Low-pass filter setting 3141 [rad/s]
PB19 VRF11 Vibration suppression control 1 - Vibration frequency 100.0 [Hz]
PB20 VRF12 Vibration suppression control 1 - Resonance frequency 100.0 [Hz]
PB21 VRF13 Vibration suppression control 1 - Vibration frequency damping 0.00
PB22 VRF14 Vibration suppression control 1 - Resonance frequency damping 0.00
PB23 VFBF Low-pass filter selection 0000h
PB24 *MVS Slight vibration suppression control 0000h
PB25 *BOP1 Function selection B-1 0000h
PB26 *CDP Gain switching function 0000h
PB27 CDL Gain switching condition 10
[kpulse/s]/
[pulse]/
[r/min]
PB28 CDT Gain switching time constant 1 [ms]
PB29 GD2B Load to motor inertia ratio/load to motor mass ratio after gain switching 7.00 [Multiplier]
PB30 PG2B Position loop gain after gain switching 0.0 [rad/s]
PB31 VG2B Speed loop gain after gain switching 0 [rad/s]
PB32 VICB Speed integral compensation after gain switching 0.0 [ms]
PB33 VRF11B Vibration suppression control 1 - Vibration frequency after gain switching 0.0 [Hz]
PB34 VRF12B
Vibration suppression control 1 - Resonance frequency after gain
switching
0.0 [Hz]
PB35 VRF13B
Vibration suppression control 1 - Vibration frequency damping after gain
switching
0.00
PB36 VRF14B
Vibration suppression control 1 - Resonance frequency damping after
gain switching
0.00
PB37 For manufacturer setting 1600
PB38 0.00
PB39 0.00
PB40 0.00
PB41 0
PB42 0
PB43 0000h
PB44 0.00
PB45 CNHF Command notch filter 0000h