APPENDIX App. - 16 (b) Using a screwdr iver To avoid da magin g housin gs and spr ings w hen wir ing with scr ewdr iver, do not pu t excess ive force. Be cautio us when c onnecti ng. 1) Adjustin g scr ew driver Diameter:…

100%1 / 710
APPENDIX
App. - 15
2) Connecting wires
a) Confirm the model number of the housing, contact and tool to be used.
b) Insert the tool diagonally into the receptacle assembly.
c) Insert the tool until it hits the surface of the receptacle assembly. At this
stage, the tool is vertical to the receptacle assembly.
d) Insert wires in the wiring hole till the end. The wires should be slightly
twisted in advance to prevent it from being loose.
It is easy to insert the wire if the wire is inserted diagonally while twisting
the tool.
e) Remove the tool.
APPENDIX
App. - 16
(b) Using a screwdriver
To avoid damaging housings and springs when wiring with screwdriver, do not put excessive force.
Be cautious when connecting.
1) Adjusting screw driver
Diameter: 2.3 mm ± 0.05 mm
Length: 120 mm or less
Width: 2.3 mm
Thickness: 0.25 mm
Angle in tip of the blade: 18 ± 1 degrees
2.3 mm ± 0.05 mm
0.25 mm
2.3 mm
18° ± 1°
Diameter: 2.5 mm ± 0.05 mm
Length: 120 mm or less
Width: 2.5 mm
Thickness: 0.3 mm
Angle in tip of the blade: 12 ± 1 degrees
0.3 mm
2.5 mm
12° ± 1°
2.5 mm ± 0.05 mm
Screwdriver diameter: φ 2.3 mm Screwdriver diameter: φ 2.5 mm
2) Connecting wires
a) Insert a screwdriver in the front slot a little diagonally, and depress the spring. While
depressing the spring, insert the wires until they hit the end. Note that the housing and spring
may be damaged if the screwdriver is inserted strongly. Never insert the screwdriver in the
wire hole. Otherwise, the connector will be damaged.
b) Pull the screwdriver out while pressing the wires. Connecting wires is completed.
c) Pull the wire lightly to confirm that the wire is surely connected.
d) To remove the wires, depress the spring by the screwdriver in the same way as connecting
wires, and then pull the wires out.
Tool insertion slot
Screw driver
APPENDIX
App. - 17
(3) Connector insertion
Insert the connector all the way straight until you hear or feel clicking. When removing the connector,
depress the lock part completely before pulling out. If the connector is pulled out without depressing the
lock part completely, the housing, contact and/or wires may be damaged.
(4) Compatible wire
Compatible wire size is listed below.
Wire size
mm
2
AWG
0.22 24
0.34 22
0.50 20
(5) Others
(a) Fix a cable tie at least distance of "A" × 1.5 away from the end of the connector.
A × 1.5 or more
A
(b) Be sure that wires are not pulled excessively when the connector is inserted.
App. 5.8.4 Wiring FG
Bottom face
Lead wire
Wire range
Single wire: φ 0.4 mm to 1.2 mm (AWG 26 to AWG 16)
Stranded wire: 0.2 mm
2
to 1.25 mm
2
(AWG 24 to AWG 16),
wire φ 0.18 mm or more