3OM-1075-002.pdf - 第170页

AHB01EDTP 3.3.3 BGA/CSP Fig. 3C23 "Recognition Data" T ab Sheet ("BGA/CSP" Selected) • • • • • Sheet Composition Each parameter is displayed or can be entered. Refer to "4.1.3 Basic Usage of T ex…

100%1 / 357
AHB01EDTP
*7 Outward length detn
Outward length tol [mm]
When "Enable (Mnl)" is set in the "Outward length detn" text box, it
is required to enter a parameter in the text box.
When "Connector (Simple)", "Connector (Complex)", "Other
Leaded (Simple)", or "Other Leaded (Complex)" is selected in
the "Component shape" text box, "Outward length detn" does
not appear.
*8 Lead width detn
Lead width tol [mm]
When "Enable (Mnl)" is set in the "Lead width detn" text box, it is
required to enter a parameter in this text box.
When "Connector (Simple)" or "Connector (Complex)" is se-
lected in the "Component shape" text box, "Lead width detn"
does not appear.
*9 Lead posn (Latl dir) detn
Lead posn (Latl dir) tol [mm]
When "Enable (Mnl)" is set in the "Lead posn (Latl dir) detn" text
box, it is required to enter a parameter in this text box.
Fig. 3C22 "Recognition Data" Tab Sheet ("IC (Simple)" Selected)
3.3 "Recognition Data" Tab
0308-004 3-33
*9
*7
*8
AHB01EDTP
3.3.3 BGA/CSP
Fig. 3C23 "Recognition Data" Tab Sheet ("BGA/CSP" Selected)
Sheet Composition
Each parameter is displayed or can be entered.
Refer to "4.1.3 Basic Usage of Text Boxes" in "Section 2" for the
detailed information on how to enter parameters.
*1 Lighting system, *2 Recognition data set, *3 Recognition
level, *4 Back ltg recog algo (Front ltg recog algo), *6 View range
set
"Back ltg recog algo" or "Front ltg recog algo" appears in *4
according to the parameter selected in the "Lighting system"
text box.
*5 Lighting pattern
Back ltg, Front ltg (Up), Front ltg (Mid), Front ltg (Dn)
When "Manual" is set in the "Ltg pattern designation" text box, it is
required to enter parameters in these text boxes.
0206-003 3-34
3.3 "Recognition Data" Tab
*5
*1
*2
*6
*7
*8
*3
*4
AHB01EDTP
0308-003 3-35
3.3 "Recognition Data" Tab
Fig. 3C23-1 "Recognition Data" Tab Sheet ("BGA/CSP" Selected)
*7 Electd pos detn
Electd pos tol [mm]
When "Enable (Mnl)" is set in the "Electd pos detn" text box, it is
required to enter a parameter in this text box.
*8 Electd size detn
Electd size tol [mm]
When "Enable (Mnl)" is set in the "Electd size detn" text box, it is
required to enter a parameter in this text box.
*9 Polarity detn
Inspection method, Polarity position X [mm], Polarity position Y [mm],
Inspection range [mm], and Inspection range image
When "Enable (Discard)" or "Enable (Placement)" is selected in the
"Polarity detn" text box, it is required to enter a parameter in each
text box.
*9
*7
*8