3OM-1075-002.pdf - 第316页
Stop timing [sec] Set the stop timing at the output conveyor buffering position in the text box. (a) Set the period of time during which the output con- veyor outlet sensor detects a P .C.B. and the con- veyor stops runn…

*2 Items
The following items are displayed in the "Parameter 1" tab sheet.
Input conveyor
Input speed [mm/sec], Speed change timing [sec], and
Stop timing [sec]
Input speed [mm/sec]
Set the input speed of the input conveyor.
The data input range is "10 to 600 mm/second".
Speed change timing [sec]
Set the period of time during which the input speed is
changed to the locate conveyor transfer speed (accelera-
tion start).
(a) This represents the period of time to elapse right
after the input conveyor has received a P.C.B. com-
pletely.
This parameter becomes valid only when there is
no buffering for the input conveyor.
(b) The data input range is "0.000 to 9.999 seconds".
Stop timing [sec]
Set the stop timing at the input conveyor buffering position in
the text box.
(a) Set the period of time during which the input con-
veyor outlet sensor detects a P.C.B. and the con-
veyor stops running.
(b) The data input range is "0.000 to 9.999 seconds".
Output conveyor
Output speed [mm/sec], Speed change timing [sec], and
Stop timing [sec]
Output speed [mm/sec]
Set the speed of the output conveyor in the text box.
The data input range is "10 to 600 mm/second".
Speed change timing [sec]
Set the period of time during which the locate conveyor trans-
fer speed is changed to the output speed (deceleration start).
(a) This represents the period of time to elapse right
after the output conveyor inlet sensor has detected
a P.C.B.
(b) The data input range is "0.000 to 9.999 seconds".
0206-002 5-83
AHB01EDTP
2.2 "Auto Operation" Tab

Stop timing [sec]
Set the stop timing at the output conveyor buffering position
in the text box.
(a) Set the period of time during which the output con-
veyor outlet sensor detects a P.C.B. and the con-
veyor stops running.
(b) The data input range is "0.000 to 9.999 seconds".
Locate conveyor
Transfer speed (High speed) [mm/sec] and Transfer speed (Re-
verse) [mm/sec]
Transfer speed (High speed) [mm/sec]
Set the speed of the locate conveyor in the text box.
The data input range is "10 to 600 mm/second".
Transfer speed (Reverse) [mm/sec]
Set the speed for reverse positioning.
The data input range is "10 to 600 mm/second".
When the "Parameter 2" tab is pressed in the "Transfer Conveyor" tab
sheet, the following tab sheet appears.
Fig. 3E75 "Transfer Conveyor" Tab Sheet
("Parameter 2" Tab Sheet)
(Provided with Multi-Layer Tray Feeder 2)
The tab sheet may look different, depending on which options are
selected.
The following items are displayed in the "Parameter 2" tab sheet.
2.2 "Auto Operation" Tab
0308-003 5-84 AHB01EDTP

Locate conveyor timing
These are items that must be specified in the operation data of
the pattern program data.
"Standard" and "Mode 1 through Mode 9" are provided.
Transfer speed (Low speed) decelerate ratio [%]
The locate conveyor works at two-stage speed.
The locate conveyor receives a P.C.B. at the high transfer
speed and the speed is reduced to the low transfer speed
until the conveyor stops at the locating position.
Set the ratio (%) of the speed deceleration.
The data input range is "0 to 99%".
Decelerate timing [sec]
Set the period of time during which the transfer speed must
be changed from "High" to "Low" after a P.C.B. has been
received at high speed and the P2 sensor has detected the
P.C.B.
The data input range is "0.000 to 9.999 seconds".
Stop timing [sec]
Set the period of time during which the P.C.B. locating posi-
tion sensor detects a P.C.B. and the conveyor stops run-
ning when "P.C.B. Priority" is set in the "P.C.B. locate
method" text box.
The data input range is "0.000 to 9.999 seconds".
Reverse stop timing [sec]
Set the period of time during which the P.C.B. locating posi-
tion sensor detects a P.C.B. and the conveyor stops run-
ning during reverse positioning.
The data input range is "0.000 to 9.999 seconds".
Acceleration ratio [%]
Set the ratio (%) of the speed deceleration compared with
the maximum acceleration of each conveyor.
The data input range is "0 to 99%".
2.2 "Auto Operation" Tab
01 12-001 5-85 AHB01EDTP