3OM-1075-002.pdf - 第314页
2.2.3 "T ransfer Conveyor" T ab • • • • • Sheet Layout When the "T ransfer Conveyor" tab is pressed in the "Auto Operation" tab sheet, the following tab sheet appears. Fig. 3E74 "T rans…

0206-002 5-81 AHB01EDTP
2.2 "Auto Operation" Tab
Output conveyor Timer
Timer #1 [sec], Timer #2 [sec], and Buffer setup
Set the time to limit the operating time (P.C.B. reception by the
output machine) of the output conveyor.
(a) Add 2 seconds (approx.) to the time required for
P.C.B. reception by the output machine and set the
time in the text box.
(b) The data input range is "0 to 99 seconds".
Timer #2 [sec]
Set the time to limit the operating time of the output conveyor to
transfer a P.C.B. on the main machine side.
The data input range is "0 to 99 seconds".
Buffer setup
Determine whether or not the P.C.B.’s should be buffered on the
output conveyor.
Set "Enable" or "Disable" in the text box.
Simultaneous transfer setup
Determine whether or not the P.C.B. on the input conveyor should
be transferred to the positioning conveyor and the P.C.B. on the
positioning conveyor to the output conveyor at the same time.
Set "Enable" or "Disable" in the text box.
P.C.B. transfer direction
Set a P.C.B. transfer direction in the text box.
"L Æ R"
The P.C.B. flows from the left to the right.
"R Æ L"
The P.C.B. flows from the right to the left.
When the setting is changed, it is required to perform
the zeroing operation again.

2.2.3 "Transfer Conveyor" Tab
••
••
• Sheet Layout
When the "Transfer Conveyor" tab is pressed in the "Auto Operation"
tab sheet, the following tab sheet appears.
Fig. 3E74 "Transfer Conveyor" Tab Sheet
("Parameter 1" Tab Sheet)
(Provided with Multi-Layer Tray Feeder 2)
The tab sheet may look different, depending on which options are
selected.
••
••
• Sheet Composition
*1 Tabs and Tab Sheets
The "Transfer Conveyor" tab sheet is provided with the following
2 tab sheets. When a tab is pressed, the corresponding tab sheet
appears.
Table 3E12
Tabs Description
Parameter 1 The corresponding tab sheet enables the operator to set the transfer
speed and stop timing of each conveyor.
Parameter 2 The corresponding tab sheet enables the operator to set the P.C.B.
transfer timing of the locate conveyor.
10 kinds of parameters are prepared.
Parameters can be set for "Mode 5" through "Mode 9" (five modes).
2.2 "Auto Operation" Tab
0308-003 5-82 AHB01EDTP
*2
*1

*2 Items
The following items are displayed in the "Parameter 1" tab sheet.
Input conveyor
Input speed [mm/sec], Speed change timing [sec], and
Stop timing [sec]
Input speed [mm/sec]
Set the input speed of the input conveyor.
The data input range is "10 to 600 mm/second".
Speed change timing [sec]
Set the period of time during which the input speed is
changed to the locate conveyor transfer speed (accelera-
tion start).
(a) This represents the period of time to elapse right
after the input conveyor has received a P.C.B. com-
pletely.
This parameter becomes valid only when there is
no buffering for the input conveyor.
(b) The data input range is "0.000 to 9.999 seconds".
Stop timing [sec]
Set the stop timing at the input conveyor buffering position in
the text box.
(a) Set the period of time during which the input con-
veyor outlet sensor detects a P.C.B. and the con-
veyor stops running.
(b) The data input range is "0.000 to 9.999 seconds".
Output conveyor
Output speed [mm/sec], Speed change timing [sec], and
Stop timing [sec]
Output speed [mm/sec]
Set the speed of the output conveyor in the text box.
The data input range is "10 to 600 mm/second".
Speed change timing [sec]
Set the period of time during which the locate conveyor trans-
fer speed is changed to the output speed (deceleration start).
(a) This represents the period of time to elapse right
after the output conveyor inlet sensor has detected
a P.C.B.
(b) The data input range is "0.000 to 9.999 seconds".
0206-002 5-83
AHB01EDTP
2.2 "Auto Operation" Tab