(4) Placement Data (P-data) U01 • • • • • Unit Control Follow the same procedure as described in "3.1 Single Pattern". • • • • • Unit P .C.B. Fiducial T able 3B28 Unit P .C.B. Recog Coord Recog Coord Recog Coor…

100%1 / 357
(2) Creation of Operation Data
P.C.B. Data
Follow the same procedure as described in "3.1 Single Pattern".
P.E.C. Recognition Data
Tabl 3B26
P.E.C. recognition function Enable
P.E.C. recognition mode Global Disable
P.E.C. recognition mode Image Enable
P.E.C. recognition mode Local Disable
P.E.C. recognition head Both Heads
P.E.C. Recognition Mark Data
Tabl 3B27
Mark # Mark Mark Size Mark Size Window Mark Type Level Recog Algo
Type D1 [mm] D2 [mm] Size [mm] Image
1 Round 1.00 0.00 05.0 Bright High Pattern
(Normal)
Setup Mark Data
Create this data when the automatic setup function is used.
(3) Creation of Placement Feeder Location Data
Follow the same procedure as described in "3.1 Single Pattern".
3.4 Repetitive Patterns (Unit P.C.B. B.B.R Enabled)
0206-002 2-70 AHB01EDTP
(4) Placement Data (P-data) U01
Unit Control
Follow the same procedure as described in "3.1 Single Pattern".
Unit P.C.B. Fiducial
Table 3B28
Unit P.C.B. Recog Coord Recog Coord Recog Coord Recog Coord Fiducial Mark Fiducial Mark
Fiducial X
1
[mm] Y
1
[mm] X
2
[mm] Y
2
[mm] FM1 FM2
Enable FX
1
FY
1
FX
2
FY
2
11
Placement Data (P-data)
Tabl 3B29
P-No. X [mm] Y [mm] Z H [mm] Fdr. No. C S HD PU
Comment V
1X
1
Y
1
000°00’ +0.00 101 - - 2 0 00
2X
2
Y
2
090°00’ +0.00 115 - - 1 0 00
3X
3
Y
3
180°00’ +0.00 105 - - 2 0 00
4 000.00 000.00 000°00’ +0.00 000 P - 0 0 00
Set "P" or "Q" as a control command in the last line (last step
No.).
(5) Creation of Placement Data (O-data) U01
Tabl 3B30
O-No. X [mm] Y [mm] Z H C Comment B-X [mm] B-Y [mm]
10X
1
0Y
1
000°00’ +0.00 - 000.00 000.00
20X
2
0Y
2
000°00’ +0.00 - 000.00 000.00
30X
3
0Y
3
000°00’ +0.00 - 000.00 000.00
4 000.00 000.00 000°00’ +0.00 E 000.00 000.00
3.4 Repetitive Patterns (Unit P.C.B. B.B.R Enabled)
0206-003 2-71 AHB01EDTP
3.5 Repetitive Patterns (Block Sorting Enabled)
Follow the same procedure as described in "3.4 Repetitive Patterns
(Unit P.C.B. B.B.R. Enabled)" except for "Placement Data (P-data)".
(1) Information on Pattern Program Creation
Example of Patterns
Fig. 3B135 General View
Fig. 3B136 Pattern 1 (Magnified View)
Method of Block Sorting
The following describes the method of block sorting according to the
outside diameters of the nozzles.
(a) Outside Diameters of Nozzles
After the nozzle IDs in the placement feeder location data
are confirmed, the outside diameters are examined, using
the nozzle type data of the nozzle data.
(b) Nozzle Type Data
When the [SYSTEM] button on the main menu bar is
pressed, the "SYSTEM SEL." menu opens. Select the
[NOZZLE DT] button.
Press the "Nozzle Data" tab in the "Nozzle Data" window.
0206-002 2-72
AHB01EDTP
3.5 Repetitive Patterns (Block Sorting Enabled)