4 . 3 "Handling Errors Per Feeder" T ab The corresponding tab sheet enables the operator to view the handling errors on each individual feeders for the current pattern program. • Sheet Layout When the "Han…

4.2 "Machine Performance Data" Tab
01 12-001 4-35 AHB01EDTP
3point errors (% of Total P.E.C. recog. errors)
Shown are the total number of errors detected on the third fiducial
mark and the percentage of the detected errors per total number
of all errors detected by the P.E.C. recognition function.
Local fiducial errors (% of Total P.E.C. recog. errors)
Shown are the total number of individual P.E.C. recognition errors
and the percentage of the detected errors per total number of all
errors detected by the P.E.C. recognition function.
Total P.E.C. recognition errors
Shown is the total number of errors detected by the P.E.C. recog-
nition function.
The number of errors detected by the global P.E.C. recognition
function and the total number of errors detected by the B.B.R.
recognition function are displayed.
*2 Vertical Scroll Bar
Scroll arrows are located at both ends of a scroll bar. The up or the
down arrow can be pressed to scroll up or down a tab sheet to
expose hidden items.

4.3 "Handling Errors Per Feeder" Tab
The corresponding tab sheet enables the operator to view the handling
errors on each individual feeders for the current pattern program.
• Sheet Layout
When the "Handling Errors Per Feeder" tab is pressed in the "Pattern
Program Management Data" window, the following tab sheet appears
inside the window.
Fig. 3D19 "Handling Errors Per Feeder" Tab Sheet
(Provided with Multi-Layer Tray Feeder 2)
The tab sheet may look different, depending on which options
are selected.
• Sheet Composition
*1 "Feeder Base #" Tabs
The "Handling Errors Per Feeder" tab sheet is divided further into
several tab sheets and each tab sheet shows the handling errors
per feeder on each individual feeder bases and trays.
When a tab is pressed, the corresponding tab sheet appears, indi-
cating that the related feeder carriage or tray is selected.
*2 Items
The following items are displayed.
(1) [Feeder No. (Actual Fdr. No.)] Button
Shown are the feeder Nos.
(2) [Total Components] Button
Each text box shows the total number of picked components (num-
ber of pick-up actions) for each individual feeders.
(3) [A: missing sensor] Button
Each text box shows the total number of component missing er-
rors detected by the vacuum sensor for each individual feeders.
4.3 "Handling Errors Per Feeder" Tab
*2
*3
*1
0206-002 4-36 AHB01EDTP

(4) [B: missing recog] Button
Each text box shows the total number of missing components
detected through recognition operation for each individual feed-
ers.
(5) [C: vacuum sensor] Button
Each text box shows the total number of component pick-up er-
rors detected by the vacuum sensor (errors not detected through
the component recognition) for each individual feeders.
(6) [D: cmpnt recog] Button
Each text box shows the total number of errors detected through
recognition operation for each individual feeders.
(7) [Total Errors] Button
Each text box shows the total number of errors detected in (3)
through (6).
(8) [Rate of Error (%)] Button
Each text box shows the percentage of the total number of errors
per the number of picked components.
(9) [Shrtg. of Cmpnt] Button
Each text box shows the total number of component shortage
errors detected for each individual feeders.
(10) Component ID
Shown are the component IDs for each individual feeders.
(11) Type
Shown are the packaging types of the related component IDs.
(12) Width
Shown are the component widths.
When one of the above buttons is pressed, the feeder No. with
the biggest parameter under the selected button is displayed in
the first line and feeder Nos. having the subsequent (second,
third, fourth, ...) biggest parameters follow.
That is, parameters are re-arranged in order of error counts
(from the biggest to the smallest ones), making it easy to ana-
lyze and improve production rate.
When the [Feeder No.] button is pressed, feeder Nos. are ar-
ranged in their initial order (order of slot Nos.).
*3 Vertical Scroll Bar
Up and down arrows are located at both ends of a scroll bar. The up
or the down arrow can be pressed to scroll up or down a tab sheet
to expose hidden parameters (data for the hidden feeder Nos.).
4.3 "Handling Errors Per Feeder" Tab
0206-002 4-37 AHB01EDTP