2.1.8.1 "Component Reject" T ab • Sheet Layout When the "Component Reject" tab is pressed in the "Unit Offset" tab sheet, the following tab sheet appears. Fig. 3E59 "Component Reject&qu…

2.1.8 "Unit Offset" Tab
• Sheet Layout
When the "Unit Offset" tab is pressed in the "Offset Data" tab sheet,
the following tab sheet appears.
Fig. 3E58 "Unit Offset" Tab Sheet
(Provided with Multi-Layer Tray Feeder 2)
The tab sheet may look different, depending on which options
are selected.
• Sheet Composition
*1 Tabs and Tab Sheets
The "Unit Offset" tab sheet is provided with the following 3 tab sheets.
Table 3E10
Tabs Description
Tray This is an optional function.
Refer to the instruction manual of the multi-layer tray feeders for de-
tails.
Component Reject The corresponding tab sheet enables the operator to set the offsets
to adjust the positional and vertical (height direction) deviations, com-
pared with the design dimensions (position) of the component stor-
age box located at the center between Feeder Bases #3 and #4.
Vibratory Stick Feeder The corresponding tab sheet enables the operator to set the offset
data for the adjustment of the positional deviations compared with the
design dimensions of Vibratory Stick Units #1 through #6.
2.1 "Offset Data" Tab
*1
0308-003 5-60 AHB01EDTP

2.1.8.1 "Component Reject" Tab
• Sheet Layout
When the "Component Reject" tab is pressed in the "Unit Offset" tab
sheet, the following tab sheet appears.
Fig. 3E59 "Component Reject" Tab Sheet
(Provided with Multi-Layer Tray Feeder 2)
The tab sheet may look different, depending on which options
are selected.
• Sheet Composition
*1 Offset Items
Set the following offset values.
Component storage box B X [mm] (Horizontal), Y [mm] (Ver-
tical), and L [mm] (Height)
Set the offsets to adjust the positional and vertical (height direc-
tion) deviations, compared with the design dimensions (position)
of the component storage box located at the center between
Feeder Bases #3 and #4. The values based on the PL-XY coordi-
nate system must be entered in each text box.
2.1 "Offset Data" Tab
0308-003 5-61 AHB01EDTP
*1

The component storage box is used to store the rejected compo-
nents in the component recognition processing.
Fig. 3E60
When the component storage box is shifted toward the lower right
directiion (viewed from the top), plus values must be enterd in the
"X [mm] (horizontal)" and "Y [mm] (vertical)" text boxes.
When the level (height) of the box is set lower than the design
value, a plus value must be entered in the "L [mm]" text box.
0206-002 5-62
AHB01EDTP
2.1 "Offset Data" Tab