3OM-1075-002.pdf - 第307页
01 12-001 5-75 AHB01EDTP 2.2 "Auto Operation" T ab Input conveyor Timer #1 [sec], Timer #2 [sec], Buffer setup, Bfr pos const transfer , and Bfr pos const transfer offset [mm] Set each parameter to specify how …

01 12-001 5-74 AHB01EDTP
2.2 "Auto Operation" Tab
This function is based on the concept that it will not be necessary
to continue automatic operation of the machine when there is no
P.C.B. on the machine and the input machine is not running auto-
matically because it is apparent that no P.C.B. can be transferred
to the machine anymore.
The machine stops automatically when a P.C.B. on the machine
is processed without unprocessed P.C.B. left on the machine
and the input machine is stopped after the last processed P.C.B.
on the machine has been transferred to the output machine.
When the machine is connected to another machine
manufactured by another company, this function may not
be activated.
Input mode
Select a parameter according to the P.C.B. unloading system of
the input machine.
Conveyor
The input machine is activated to receive a P.C.B. from the input
machine when the P.C.B. transfer signal is received from the
input machine.
Pusher
The pusher of the input machine forces a P.C.B. out to the input
conveyor of the machine.
When the P.C.B. detection sensor (for the pusher) is not pro-
vided at the inlet side of the input conveyor, do not set "Pusher" in
the text box.
SMEMA
(Not Available)
P.C.B.’s are transferred according to the "SMEMA" standard.
Conveyor #2
The P.C.B. on the conveyor can be transferred only when a P.C.B.
request signal is received.

01 12-001 5-75 AHB01EDTP
2.2 "Auto Operation" Tab
Input conveyor
Timer #1 [sec], Timer #2 [sec], Buffer setup, Bfr pos const
transfer, and Bfr pos const transfer offset [mm]
Set each parameter to specify how the input conveyor should work.
Timer #1 [sec]
Set the time to limit the operating time (P.C.B. reception from the
input machine) of the input conveyor.
This timer measures the operating time of the input conveyor
and is used to detect an interrupted P.C.B.
(a) Add 2 seconds (approx.) to the time required for
P.C.B. reception from the input machine and set the
time in the text box.
(b) The data input range is "0 to 99 seconds".
Timer #2 [sec]
Set the time to limit the operating time of the input conveyor to
transfer a P.C.B. on the main machine side.
This timer measures the operating time of the input conveyor
and is used to detect an interrupted P.C.B.
The data input range is "0 to 99 seconds".
Buffer setup
Determine whether or not the P.C.B.’s should be buffered on
the input conveyor.
Set "Enable" or "Disable" in the text box.
Bfr pos const transfer
Determine whether or not the constant P.C.B. transfer system
should be used or not. When the system is used, the constant
number of P.C.B.’s (detected by the P.C.B. detection L1 sen-
sor) are transferred to the buffering position on the input con-
veyor without the P.C.B. detection L2 sensor being used.
Set "Enable" or "Disable" in the text box.
"Enable" improves the productivity.

Bfr pos const transfer offset [mm]
The parameters (Locate mode, Y clamp timer [sec], Z clamp timer
[sec], Conveyor buffer setup, and P.C.B. detection off delay time
[sec]) can be specified for the P.C.B. positioning section.
Locate mode
Set the sequence in which a P.C.B. should be transferred and
positioned. Select "Priority P.C.B. Flow" or "Placement reference".
"Priority P.C.B. Flow"
Select this when the placement coordinate reference for the
P.C.B. must be specified on the opposite side of the P.C.B.
stopper location for P.C.B. positioning.
"Placement reference"
Select this when the placement coordinate reference must be
specified on the side where the P.C.B. is pushed against the
P.C.B. stopper.
Push the P.C.B. against the P.C.B. stopper for position-
ing.
When an area of the P.C.B. has a cutout, etc., and is
pushed against the P.C.B. stopper, the P.C.B. cannot be
positioned correctly.
0206-002 5-76
AHB01EDTP
2.2 "Auto Operation" Tab