Fig. 3E67 The finished P .C.B. on the P .C.B. positioning section is set in the standby mode until the subsequent P .C.B. comes to "Area A" shown in the figure. When "Enable" is set in the "Auto …

100%1 / 357
2.2.2 "P.C.B. Transfer Mode Setup" Tab
Sheet Layout
When the "P.C.B. Transfer Mode Setup" tab is pressed in the "Auto
Operation" tab sheet, the following tab sheet appears.
Fig. 3E66 "P.C.B. Transfer Mode Setup" Tab Sheet
(Provided with Multi-Layer Tray Feeder 2)
The tab sheet may look different, depending on which options are
selected.
Sheet Composition
*1 Items
The following items are displayed.
Auto transfer mode
Set "Enable" or "Disable" in the text box to determine whether or
not the automatic transfer function should be used.
When "Disable" (Standard) is set, P.C.B.
,
s are transferred
as follows
The finished P.C.B. (where components are already placed) on
0308-003 5-72
AHB01EDTP
2.2 "Auto Operation" Tab
*1
Fig. 3E67
The finished P.C.B. on the P.C.B. positioning section is set in the
standby mode until the subsequent P.C.B. comes to "Area A"
shown in the figure.
When "Enable" is set in the "Auto transfer mode" text box,
P.C.B.’s are transferred as follows.
When the components are placed completely on the P.C.B. in
the P.C.B. positioning section, no P.C.B. is located on (A), and
the conveyor transfer is not started up, the P.C.B. transfer func-
tion is activated and the finished P.C.B. is discharged to the out-
put machine.
This function works efficiently to avoid finished P.C.B. stagnation
on the P.C.B. positioning section when the line balance between
the machine and the input machine is not good.
Auto stop mode
"Enable" or "Disable" can be set in this text box to determine
whether or not the automatic stop function should be used.
When "Enable" (standard mode) is set in the text box, the
automatic stop function works in the following cases.
The machine stops when the automatic operation is started by
pressing the [START] button with the machine in the initialized
mode (no P.C.B. on the machine), the machine is waiting for a
P.C.B. to be sent from the input machine and detects that "RUN"
signal has stopped coming from the input machine, and the ma-
chine is kept in the condition for 2 seconds.
0206-002 5-73
AHB01EDTP
2.2 "Auto Operation" Tab
A
A
P.C.B. Transfer Direction [L R]
P.C.B. Positioning Section
P.C.B. Positioning Section
P.C.B. Transfer Direction [R L]
01 12-001 5-74 AHB01EDTP
2.2 "Auto Operation" Tab
This function is based on the concept that it will not be necessary
to continue automatic operation of the machine when there is no
P.C.B. on the machine and the input machine is not running auto-
matically because it is apparent that no P.C.B. can be transferred
to the machine anymore.
The machine stops automatically when a P.C.B. on the machine
is processed without unprocessed P.C.B. left on the machine
and the input machine is stopped after the last processed P.C.B.
on the machine has been transferred to the output machine.
When the machine is connected to another machine
manufactured by another company, this function may not
be activated.
Input mode
Select a parameter according to the P.C.B. unloading system of
the input machine.
Conveyor
The input machine is activated to receive a P.C.B. from the input
machine when the P.C.B. transfer signal is received from the
input machine.
Pusher
The pusher of the input machine forces a P.C.B. out to the input
conveyor of the machine.
When the P.C.B. detection sensor (for the pusher) is not pro-
vided at the inlet side of the input conveyor, do not set "Pusher" in
the text box.
SMEMA
(Not Available)
P.C.B.’s are transferred according to the "SMEMA" standard.
Conveyor #2
The P.C.B. on the conveyor can be transferred only when a P.C.B.
request signal is received.