T able 3E8 T abs Description Component Recog The corresponding tab sheet enables the operator to set the offset Movable Camera data for adjustment of positional and angular deviations compared with the design dimensions …

100%1 / 357
2.1.6 "Camera" Tab
Sheet Layout
When the "Camera" tab is pressed in the "Offset Data" tab sheet, the
following tab sheet appears.
Fig. 3E47 "Camera" Tab Sheet
Sheet Composition
*1 Tabs and Tab Sheets
The "Camera" tab sheet is provided with the following 4 tabs.
When each tab is pressed, the corresponding tab sheet appears.
2.1 "Offset Data" Tab
0308-004 5-45 AHB01EDTP
*1
Table 3E8
Tabs Description
Component Recog The corresponding tab sheet enables the operator to set the offset
Movable Camera data for adjustment of positional and angular deviations compared
with the design dimensions of the component recognition movable
camera center position (viewed from the P.C.B. positioning X/Y coor-
dinates).
Component Recog The corresponding tab sheet enables the operator to set the offset
Fixed Camera data for adjustment of positional and angular deviations compared
with the design dimensions of the component recognition fixed cam-
era center position (viewed from the P.C.B. positioning X/Y coordi-
nates).
Component Recog The corresponding tab sheet enables the operator to set the magnifi-
Magnification cations of the component recognition cameras and the gain and level
Gain Level (the amplification at which the image signals captured by the camera
is converted into picture information, representing brightness) of each
camera.
P.E.C. Recog Camera The corresponding tab sheet enables the operator to set the offset
data for horizontal swing adjustment of the P.E.C. recognition cam-
era.
2.1 "Offset Data" Tab
0206-003 5-46 AHB01EDTP
2.1.6.1 "Component Recog Movable Camera" Tab
Sheet Layout
When the "Component Recog Movable Camera" tab is pressed in
the "Camera" tab sheet, the following tab sheet appears.
Fig. 3E48 "Component Recog Movable Camera" Tab Sheet
Sheet Composition
*1 Offset Items
Set the offset values related to each nozzle (1 through 6) for the
movable cameras (M1 and M2).
L [mm] (Height), Z (Angle) [deg], and NC (Angle) [deg]
(Not Available)
This offset data is used to optimize the component recognition that
will be made, using the movable cameras.
2.1 "Offset Data" Tab