3OM-1075-002.pdf - 第42页

1-Point Recognition Only the X and Y elements are corrected. The θ element (expansion, etc.) is not corrected. Fig. 3B30 2-Point Recognition Specify fiducial mark positions so that one fiducial mark is kept as diagonally…

100%1 / 357
(A02) P.E.C. Recognition Data
Fig. 3B27 Edit Window (Example)
(A02_01) P.E.C. recognition function
Select one of the following options to determine whether or
not this function should be used.
Disable : The P.E.C. recognition function is not used.
Enable : The P.E.C. recognition function is used.
P.E.C. recognition mode Global
When "Enable" is selected, set one of the following options
as a global recognition mode.
Disable : The global recognition function is not activated.
1 Point : The global recognition function is implemented,
using one fiducial mark.
2 Point : The global recognition function is implemented,
using two fiducial marks.
3 Point : The global recognition function is implemented,
using three fiducial marks.
0308-004 2-22
AHB01EDTP
2.3 Operation Data
P.E.C. recognition mode Global
Fig. 3B29
2 Point
P.E.C. recognition function
Fig. 3B28
Enable
1-Point Recognition
Only the X and Y elements are corrected. The θ element
(expansion, etc.) is not corrected.
Fig. 3B30
2-Point Recognition
Specify fiducial mark positions so that one fiducial mark is
kept as diagonally away from the other as possible.
Fig. 3B31
Avoid fiducial mark positions aligned horizontally or
vertically with each other as shown below.
Fig. 3B32
3-Point Recognition
Specify fiducial mark positions so that the triangle are formed
by connecting the three points (three fiducial marks) be-
comes as large as possible.
Fig. 3B33
When any two of the three fiducial marks are desig-
nated to be positioned as close as possible to each
other, the results of the correction will be almost the
same as "2-Point Recognition".
0206-003 2-23 AHB01EDTP
2.3 Operation Data
P.E.C. recognition mode Image
When "Enable" is set in "P.E.C. recognition function", set
one of the following options as an image recognition mode.
Disable : The image recognition function is not used.
Enable : The image recognition function is used.
Fig. 3B35
When the global recognition function is used together
with the image recognition function, both recogniz-
ing actions take place but the placement coordinates
are corrected according to the result of the image
recognition.
0206-003 2-24 AHB01EDTP
2.3 Operation Data
P.E.C. recognition mode Image
Fig. 3B34
Disable