3OM-1075-002.pdf - 第265页

Head 2 Nozzle 1 through 6 X [mm] (Horizontal) and Y [mm] (V ertical) The NC axis is rotated such that a nozzle on Head #2 is specified as Nozzle #1. This offset data is used to set the distance between the scanning coord…

100%1 / 357
Fig. 3E34
When the rotational center of Head #1 is actually located at the po-
sition shown in Fig. 3E34, the offset parameters representing the X
(horizontal) must be provided with a minus (-) sign and the offset
parameter representing the Y (vertical) with a plus (+) sign.
This offset data is calculated through teaching operation which is
performed, using the jig component stationed at the teaching plate
inside the machine.
2.1 "Offset Data" Tab
0206-003 5-33 AHB01EDTP
Head 2 Nozzle 1 through 6
X [mm] (Horizontal) and Y [mm] (Vertical)
The NC axis is rotated such that a nozzle on Head #2 is specified
as Nozzle #1.
This offset data is used to set the distance between the scanning
coordinate center (actual position) of the P.E.C. camera on the beam
and the rotational center of Head #2 (Nozzle #1). The distances
deviating from the design values must be entered in each text box.
The parameters must be those viewed in the coordinate system
(PL-XY) for P.C.B. positioning.
As for Nozzles #2 through #6, the offset data is set in the same way
as Nozzle #1.
Fig. 3E35
When the rotational center of Head #1 is actually located at the po-
sition shown in Fig. 3E35, the offset parameter representing the X
(horizontal) must be provided with a minus (-) sign and the offset
parameter representing the Y (vertical) with a plus (+) sign.
This offset data is calculated through teaching operation which is
performed, using the jig component stationed at the teaching plate
inside the machine.
2.1 "Offset Data" Tab
0206-003 5-34 AHB01EDTP
2.1.4.2 "Head Offset" Tab
Sheet Layout
When the "Head Offset" tab is pressed in the "Head" tab sheet, the
following tab sheet appears.
Fig. 3E36 "Head Offset" Tab Sheet
Sheet Composition
*1 Offset Items
Set the following offset values.
Fixed camera A1 Head (1 and 2)
X [mm] (Horizontal) and Y [mm] (Vertical)
This offset data is used to adjust the positional deviations compared
with the design dimensions representing the center of the compo-
nent recognition camera viewed from the P.C.B. positioning X coor-
dinate.
2.1 "Offset Data" Tab
0308-004 5-35 AHB01EDTP
*1