(C02_04) X [mm], Y [mm] Set Coordinates X and Y for component placement. The coordinates must be based on the placement coordi- nate reference point (N 0 ). Unit: mm Fig. 3B101 Do not set any coordinates for component pl…

Recog Coord X1 [mm], Recog Coord Y1 [mm]
Set the X1 and Y1 coordinates of the first fiducial mark based
on the pattern origin.
Unit: mm
Recog Coord X2 [mm], Recog Coord Y2 [mm]
Set the X2 and Y2 coordinates of the second fiducial mark
based on the pattern origin.
Unit: mm
Fiducial Mark FM1, Fiducial Mark FM2
Set the mark Nos. of the first and second fiducial marks
FM1 and FM2.
Select the mark Nos. (Mark #) specified in the P.C.B. recog-
nition mark data of the operation data.
(C02_03) P-No.
Shown are the step Nos. of the placement data (P).
Set coordinates and angles for component placement in the
lines of the step Nos. (P-Nos.).
2.5 Placement Data
Fig. 3B96
Recog Coord Y1 [mm]
Recog Coord X1 [mm]
000.000
000.000
Fig. 3B97
Recog Coord Y2 [mm]
Recog Coord X2 [mm] 100.000
100.000
0206-002 2-49 AHB01EDTP
01
01
Fiducial Mark FM1
Fig. 3B98
Fiducial Mark FM2
Fig. 3B99
P-No.
1

(C02_04) X [mm], Y [mm]
Set Coordinates X and Y for component placement.
The coordinates must be based on the placement coordi-
nate reference point (N
0
).
Unit: mm
Fig. 3B101
Do not set any coordinates for component placement in the last
line (last step No.).
Keep them as "000.00".
0206-002 2-50
AHB01EDTP
2.5 Placement Data
X [mm]
Fig. 3B100
Y [mm]
010.00
010.00

(C02_05) Z=theta
Set angles for component placement.
Data Input Range: 0°00′ to 359°59′
The placement angles must be determined according to the
packaged posture of components on the tape feeder or the
multi-layer tray feeder (option).
Example:
Fig. 3B103
Do not set any angle for component placement in the last line
(last P-No.).
Keep it as "000°00′".
Z
(Angle)
0° 45° 90° 135° 180° 225° 270° 315°
0°
270°
180°
90°
Feeder Base #1
and Multi-Layer
Tray Feeder
(Option)
Packaged
Posture
User Direction
of Tape Feed
Feeder Bases #3
and #4
Packaged
Posture
User Direction
of Tape Feed
Rear View of Machine
Packaged Posture of Component on Feeder
Tape Feeder
Multi-Layer Tray Feeder (Option)
P. C. B .
Front View of Machine
Tape Feeder
0206-003 2-51 AHB01EDTP
2.5 Placement Data
045°00′
Z
Fig. 3B102