3 . 6 "Nozzle Management Data" T ab The corresponding tab sheet enables the operator to view the nozzle management data for each individual heads/nozzles. • Sheet Layout When the "Nozzle Management Data&qu…

(5) [C: vacuum sensor] Button
Each text box shows the total number of component pick-up er-
rors detected by the vacuum sensor (errors not detected through
the component recognition) for each individual feeders.
(6) [D: cmpnt recog] Button
Each text box shows the number of component recognition er-
rors.
(7) [Total Errors] Button
Each text box shows the total number of errors in (3) through (6).
(8) [Rate of Error (%)] Button
Each text box shows the percentage of error per number of picked
components.
(9) [Head Clear/Change Date] Button
Each text box shows the clear date for each individual heads.
(based on head bypassing, etc.)
When one of the above buttons is pressed, the feeder No. with
the biggest parameter under the selected button is displayed in
the first line and feeder Nos. having the subsequent (second,
third, fourth, ...) biggest parameters follow. That is, parameters
are re-arranged in order of error counts, making it easy to ana-
lyze and improve production rate.
When the [Head No.] button is pressed, head Nos. are arranged
in their initial order (order of head Nos.).
3.5 "Head Management Data" Tab
01 12-001 4-23 AHB01EDTP

3.6 "Nozzle Management Data" Tab
The corresponding tab sheet enables the operator to view the nozzle
management data for each individual heads/nozzles.
• Sheet Layout
When the "Nozzle Management Data" tab is pressed in the "Manage-
ment Data" window, the following tab sheet appears inside the window.
Fig. 3D14 "Nozzle Management Data" Tab Sheet
• Sheet Composition
*1 Items
The following items are displayed.
(1) [Stk. - Add.] Button
Shown are the nozzle stocker and address Nos.
(2) [Total Nozzle Usage] Button
Each text box shows the number of pick-up actions for each indi-
vidual nozzles.
(3) [A: missing sensor] Button
Each text box shows the number of component missing errors
detected by the vacuum sensor for each individual nozzles.
3.6 "Nozzle Management Data" Tab
01 12-001 4-24 AHB01EDTP
*2
*1
*3

(4) [B: missing recog] Button
Each text box shows the number of missing components de-
tected through recognition operation for each individual nozzles.
(5) [C: vacuum sensor] Button
Each text box shows the number of component pick-up errors
detected by the vacuum sensor (errors not detected through the
component recognition) for each individual feeders.
(6) [D: cmpnt recog] Button
Each text box shows the number of errors detected through rec-
ognition operation for each individual nozzles.
(7) [Total Errors] Button
Each text box shows the total number of errors detected in (2)
through (6).
(8) [Rate of Error (%)] Button
Each text box shows the percentage of the total number of errors
per the number of picked components.
(9) [Nozzle Clear/Change Date] Button
Each text box shows the clear date for each individual nozzles.
When one of the above buttons is pressed, the stocker address
with the biggest parameter under the selected button is dis-
played in the first line and stocker addresses having the subse-
quent (second, third, fourth, ...) biggest parameters follow.
That is, parameters are re-arranged in order of error counts
(from the biggest to the smallest ones), making it easy to ana-
lyze and improve production rate.
When the [Stk. - Add.] button is pressed, the stocker-address
Nos. are arranged in their initial order (order of nozzle stocker
Nos. - nozzle address Nos.).
*2 Vertical Scroll Bar
Scroll arrows are located at both ends of a scroll bar. The up or the
down arrow can be pressed to scroll up or down a tab sheet to
expose hidden nozzle stocker and address Nos.
*3 Horizontal Scroll Bar
Right and left arrows are located at both ends of a scroll bar. The
right or the left arrow can be pressed to scroll right or left a tab sheet
to expose hidden parameters (data for the hidden head-nozzle Nos.).
3.6 "Nozzle Management Data" Tab
0206-002 4-25 AHB01EDTP