3OM-1075-002.pdf - 第328页

01 12-001 5-95 AHB01EDTP *6 Fiducial Mark Image Specify how (bright or dark) the image of the nozzle tip is cap- tured in the front lighting system. Select one of the following options. Bright or Dark (a) The set paramet…

100%1 / 357
0206-002 5-94 AHB01EDTP
*4 Tip Polarity
Set the polarity of the nozzle tip (shape).
Enable : Special Nozzle with Polarity (Asymmetrical)
Disable : Round Nozzle or the like without Polarity
Fig. 3E82
*5 Nozzle Outline X [mm] (Horizontal), Nozzle Outline Y [mm]
(Vertical)
Set the outer dimensions of the nozzle tip section.
Data Input Range
X: 0.00 to 18.00
Y: 0.00 to 18.00
In the case of "Circle", set the same dimensions for "X" and "Y".
In the case of "Rectangle", set Dimensions X and Y.
Fig. 3E83
3.2 "Nozzle Data" Tab
*5 *6 *7 *8
X
Y
X
Y
A
A
Imprinted Nozzle ID
Imprinted Nozzle ID
Diffusion Plate
Diffusion Plate
01 12-001 5-95 AHB01EDTP
*6 Fiducial Mark Image
Specify how (bright or dark) the image of the nozzle tip is cap-
tured in the front lighting system.
Select one of the following options.
Bright or Dark
(a) The set parameter is required for nozzle masking in the
front lighting system.
(b) In normal cases, set "Bright" in each text box.
*7 Lighting Method
Specify which lighting method can be used for each nozzle.
Select one of the following options.
Back-Lighting, Front-Lighting, Back/Front
"Front-Lighting" must be selected for such a nozzle that the
image of the area other than the nozzle tip appears dark in the
back lighting system.
"Back-Lighting" must be selected for such a nozzle that the
image of the area other than the nozzle tip appears bright in the
front lighting system.
*8 V-Groove Size [mm]
When the V-grooved nozzle is used for cylindrical components, set
the size of the V groove in the corresponding text box.
Data Input Range
00.00 to 18.00
In the case of the nozzle without a V groove, set "0" (zero) in the
corresponding text box.
3.2 "Nozzle Data" Tab
Fig. 3E84
*9 Eccentric Distance X [mm], Y [mm]
In the case of the special nozzle whose tip is manufactured eccen-
trically from the head rotational center, set the eccentricity (distances)
separately for the "X" and "Y" directions.
Data Input Range
X: 99.99 to +99.99
Y: 99.99 to +99.99
Fig. 3E85
(a) Set "0, 0" as the data values (X, Y) for all the standard
nozzles.
(b) By pressing one of the titles (the labels arranged on
top of the list), the parameters can be sorted by "Nozzle
ID", "Length [mm]" , etc., and reorganized, depending
on which title is selected.
3.2 "Nozzle Data" Tab
0206-002 5-96 AHB01EDTP
*9
*10
X(+)
Y (-)
Y (+)
X(-)
A
A
Diffusion Plate
Imprinted Nozzle ID
Nozzle Center
Nozzle Rotational Center