3OM-1075-002.pdf - 第325页
• • • • • Operation Procedure Nozzle T ype Change Operation (1) Select the nozzle ID in the address where the nozzle type must be changed and press the [ ] icon. The "Nozzle T ype" window opens. Fig. 3E80 "…

*3 Nozzle ID
Nozzle IDs can be specified.
When an arbitrary nozzle ID is selected and the [ ] icon is
pressed, the "Nozzle Type" window opens.
Double-clicking the "Nozzle ID" (title) also opens the "Nozzle
Type" window.
*4 Direction [
° °
° °
° ]
(Not Available)
In principle, "000" (0
°°
°°
°) must be specified.
This is the reserved data for special nozzles, etc., that are used
to place special component.
*5 C
Set control commands in the text boxes.
- : This command handles the steps as those used for com-
ponent placement.
S : This command invalidates the steps.
This command prohibits the use of the nozzle in the stocker ad-
dress where the nozzle ID is already set.
When "S" (bypass designation) is set, the control process is
handled in the same way as the blank setting.
01 12-001 5-91
AHB01EDTP
3.1 "Nozzle Stocker Data" Tab

••
••
• Operation Procedure
Nozzle Type Change Operation
(1) Select the nozzle ID in the address where the nozzle type must
be changed and press the [ ] icon.
The "Nozzle Type" window opens.
Fig. 3E80 "Nozzle Type" Window
The line of the nozzle ID selected in (1) is highlighted in the "Nozzle
Type" window.
(2) Select the nozzle type to be allocated and press the [OK] button.
The source nozzle type is changed to the selected one.
It is recommended for better efficiency that the nozzles for
Head #1 be stored in Nozzle Stocker B1 and the nozzles for
Head #2 in Nozzle Stocker B2.
0206-002 5-92
AHB01EDTP
3.1 "Nozzle Stocker Data" Tab

0206-002 5-93 AHB01EDTP
3.2 "Nozzle Data" Tab
3.2 "Nozzle Data" Tab
••
••
• Sheet Layout
When the "Nozzle Data" tab is pressed in the "Nozzle Data" window,
the following tab sheet appears inside the window.
Fig. 3E81 "Nozzle Data" Tab Sheet
••
••
• Sheet Composition
*1 Nozzle ID
Shown are the nozzle IDs (names).
*2 Shape Code
Set a nozzle shape in each text box.
"Circle" or "Rectangle" can be selected.
In the case of a rectangular nozzle, the pre-rotational pick-up
control (control based on the parameter set in the "Pickup angle
[ ° ]" text box in the "Component Library" edit window) may be
required depending on the packaged posture of a component.
Refer to the instruction manual of the component library for de-
tails.
*3 Length [mm]
Set the nozzle length in this text box.